CQM1-CIF01 Omron, CQM1-CIF01 Datasheet - Page 129

no-image

CQM1-CIF01

Manufacturer Part Number
CQM1-CIF01
Description
PERIPHERAL CABLE FOR NEC COMP.
Manufacturer
Omron
Datasheet

Specifications of CQM1-CIF01

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
108
Position Control Unit Error Logs
Positioning
sequences
Dwell times
Item
Sequence data error 3000
Dwell time error
Name
to
3099
4001
to
4019
Code
One of the following errors occurred in
the positioning sequence:
The completion code is not in the range
0 to 6.
The initial speed number is not in the
range 00 to 99.
The acceleration time number is not in
the range 0 to 9.
The deceleration time number is not in
the range 0 to 9.
The target speed number is not in the
range 00 to 99.
The dwell time number is not in the
range 00 to 19.
One of the following errors occurred in
the axis designation:
The Y, Z, or U axis was specified for a 1-
axis Position Control Unit.
The Z or U axis was specified for a 2-
axis Position Control Unit.
More than one axis is specified for inter-
rupt feeding or speed control, or all axis
designation settings are set to 0.
(The last two digits of the code indicate
the position data number (00 to 99)
where the error occurred.)
These codes indicate that a dwell time
is outside the settable range (0 to 9.99
s).
(The last two digits of the code indicate
the dwell time number (00 to 19) where
the error occurred.)
Cause
Transfer the data
again after
checking and
correcting it.
Clearing
method
Section 11-1
When this
error occurs
during data
transfer, all
data (includ-
ing the data
with the error)
specified for
transfer will
be lost.
All operating
axes will be
decelerated
to a stop.
Operation
after error

Related parts for CQM1-CIF01