CQM1-CIF01 Omron, CQM1-CIF01 Datasheet - Page 137

no-image

CQM1-CIF01

Manufacturer Part Number
CQM1-CIF01
Description
PERIPHERAL CABLE FOR NEC COMP.
Manufacturer
Omron
Datasheet

Specifications of CQM1-CIF01

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
116
Position Control Unit Error Logs
Intelligent
Read/Write
Flash
memory
Group
IORD format
error
IOWR format
error
Flash mem-
ory error
Name
8700
8701
9300
Code
One of the following errors
occurred when the IORD instruc-
tion was executed:
The Position Control Unit’s
address was outside the settable
range.
One of the following errors
occurred when the IOWR instruc-
tion was executed:
The Position Control Unit’s
address was outside the settable
range.
The parameters for the origin
search high speed and the origin
search proximity speed were not
sent together.
An attempt was made to save
data to flash memory, but the data
couldn’t be saved because of a
problem with the flash memory.
Cause
Execute the instruc-
tion again after correct-
ing the data.
Execute the data save
operation again. The
error will be cleared if
the data is written nor-
mally. Replace the Unit
if the error occurs
again.
(In some cases the
data save operation
can take up to 30 s.)
Clearing method
The current data trans-
fer will not be exe-
cuted, but other
operating axes will not
be affected.
The current instruc-
tion will not be exe-
cuted.
All axes will be decel-
erated to a stop.
Operation after error
Section 11-1

Related parts for CQM1-CIF01