Default Configurations for Connecting Online
Default Configurations for Connecting Online
Setting and Changing Communications Specifications
CPU and Position Control Units Default Configuration
Connecting Directly to PLCs
1,2,3...
Note
Online connection enables using the following CX-Position software functions.
The following PLC settings are required to connect the CX-Position software
online to a PLC using serial communications (with the Host Link protocol or
Toolbus) and execute the functions in the previous list.
1. Set the Position Control Unit’s unit number using the rotary switch on the
2. Set the DIP switch on the CPU Unit or Controller Section of the NSJ Con-
3. Create the I/O tables (using the CX-Programmer or Programming Con-
When connecting directly to a PLC through a Toolbus or Host Link connection,
the communications specifications have been set when the PLC was added.
For details, see 3-2 Adding and Deleting PLCs. To change or check the com-
munications specifications, use the Properties settings.
1. When using the CX-Position simultaneously with the CX-Programmer, the
2. When using the CX-Position simultaneously with Programming Devices
• Download to NC
• Upload from NC
• Verify
• Write Flash Memory
• Monitor
• Monitor Units
• Monitor NC Operating Memory Area
• Monitor NC Operating Data Area
• View NC Error Log
front panel.
troller.
a) When Communications Are Established with Toolbus
b) When Communications Are Established with SYSMAC WAY (Host
sole).
same communications setting should be used. If different settings are
made, a communications error will occur.
such as the CX-Programmer, the CX-Protocol, etc., a communications er-
• When using a peripheral port, set pin 4 to OFF, or set pin 4 to ON and
• When using an RS-232C port, set pin 5 to ON, or set pin 5 to OFF and
• When using a peripheral port, set pin 4 to ON, or perform the PLC Set-
• When using an RS-232C port, set pin 5 to OFF, or perform the PLC
perform PLC Settings (set the PLC Setup address 144 to 0400 Hex).
perform PLC Settings (set the PLC Setup address 160 to 0400 Hex).
Link)
tings (set the PLC Setup address 144 to 0000 Hex (default setting)).
Settings (set the PLC Setup address 160 to 0000 Hex (default set-
ting)).