OM13005,598 NXP Semiconductors, OM13005,598 Datasheet - Page 115

BOARD EVAL EM773 METER US PLUG

OM13005,598

Manufacturer Part Number
OM13005,598
Description
BOARD EVAL EM773 METER US PLUG
Manufacturer
NXP Semiconductors
Type
Other Power Managementr
Datasheets

Specifications of OM13005,598

Design Resources
Plug Meter Schematics, Gerber Files USB Dongle Schematics, Gerber Files
Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 32-Bit
Utilized Ic / Part
EM773FHN33,551
Interface Type
USB
Maximum Operating Temperature
+ 150 C
Operating Supply Voltage
1.8 V to 3.6 V
Product
Power Management Development Tools
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Primary Attributes
-
Secondary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
EM773, OL2381
Other names
568-6680
NXP Semiconductors
UM10415
User manual
10.11.1 Master Transmitter mode
Table 127. Abbreviations used to describe an I
In
The numbers in the circles show the status code held in the I2STAT register. At these
points, a service routine must be executed to continue or complete the serial transfer.
These service routines are not critical since the serial transfer is suspended until the serial
interrupt flag is cleared by software.
When a serial interrupt routine is entered, the status code in I2STAT is used to branch to
the appropriate service routine. For each status code, the required software action and
details of the following serial transfer are given in tables from
In the master transmitter mode, a number of data bytes are transmitted to a slave receiver
(see
initialized as follows:
Table 128. I2CONSET used to initialize Master Transmitter mode
The I
set to logic 1 to enable the I
acknowledge its own slave address or the General Call address in the event of another
device becoming master of the bus. In other words, if AA is reset, the I
enter a slave mode. STA, STO, and SI must be reset.
Abbreviation
S
SLA
R
W
A
A
Data
P
Bit
Symbol
Value
Figure 23
Figure
2
C rate must also be configured in the I2SCLL and I2SCLH registers. I2EN must be
7
-
-
23). Before the master transmitter mode can be entered, I2CON must be
to
Figure
All information provided in this document is subject to legal disclaimers.
6
I2EN
1
Rev. 1 — 10 September 2010
27, circles are used to indicate when the serial interrupt flag is set.
Explanation
START Condition
7-bit slave address
Read bit (HIGH level at SDA)
Write bit (LOW level at SDA)
Acknowledge bit (LOW level at SDA)
Not acknowledge bit (HIGH level at SDA)
8-bit data byte
STOP condition
2
C block. If the AA bit is reset, the I
5
STA
0
4
STO
0
2
C operation
Chapter 10: EM773 I2C-bus interface
3
SI
0
2
AA
x
Table 129
2
C block will not
2
UM10415
-
1
-
C interface cannot
© NXP B.V. 2010. All rights reserved.
to
Table
135.
0
-
-
115 of 310