OM13005,598 NXP Semiconductors, OM13005,598 Datasheet - Page 124

BOARD EVAL EM773 METER US PLUG

OM13005,598

Manufacturer Part Number
OM13005,598
Description
BOARD EVAL EM773 METER US PLUG
Manufacturer
NXP Semiconductors
Type
Other Power Managementr
Datasheets

Specifications of OM13005,598

Design Resources
Plug Meter Schematics, Gerber Files USB Dongle Schematics, Gerber Files
Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 32-Bit
Utilized Ic / Part
EM773FHN33,551
Interface Type
USB
Maximum Operating Temperature
+ 150 C
Operating Supply Voltage
1.8 V to 3.6 V
Product
Power Management Development Tools
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Primary Attributes
-
Secondary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
EM773, OL2381
Other names
568-6680
NXP Semiconductors
Table 133. Slave Receiver mode
UM10415
User manual
Status
Code
(I2CSTAT)
0x98
0xA0
Status of the I
and hardware
Previously addressed
with General Call;
DATA byte has been
received; NOT ACK
has been returned.
A STOP condition or
Repeated START
condition has been
received while still
addressed as
SLV/REC or
SLV/TRX.
2
C-bus
…continued
Application software response
To/From I2DAT
Read data byte or 0
Read data byte or 0
Read data byte or 1
Read data byte
No STDAT action
or
No STDAT action
or
No STDAT action
or
No STDAT action
All information provided in this document is subject to legal disclaimers.
Rev. 1 — 10 September 2010
To I2CON
STA STO SI
1
0
0
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
AA
1
1
0
1
0
1
0
0
Chapter 10: EM773 I2C-bus interface
Next action taken by I
Switched to not addressed SLV mode; no
recognition of own SLA or General call
address.
Switched to not addressed SLV mode;
Own SLA will be recognized; General call
address will be recognized if
I2ADR[0] = logic 1.
Switched to not addressed SLV mode; no
recognition of own SLA or General call
address. A START condition will be
transmitted when the bus becomes free.
Switched to not addressed SLV mode;
Own SLA will be recognized; General call
address will be recognized if
I2ADR[0] = logic 1. A START condition
will be transmitted when the bus becomes
free.
Switched to not addressed SLV mode; no
recognition of own SLA or General call
address.
Switched to not addressed SLV mode;
Own SLA will be recognized; General call
address will be recognized if
I2ADR[0] = logic 1.
Switched to not addressed SLV mode; no
recognition of own SLA or General call
address. A START condition will be
transmitted when the bus becomes free.
Switched to not addressed SLV mode;
Own SLA will be recognized; General call
address will be recognized if
I2ADR[0] = logic 1. A START condition
will be transmitted when the bus becomes
free.
UM10415
© NXP B.V. 2010. All rights reserved.
2
C hardware
124 of 310