OM13005,598 NXP Semiconductors, OM13005,598 Datasheet - Page 190

BOARD EVAL EM773 METER US PLUG

OM13005,598

Manufacturer Part Number
OM13005,598
Description
BOARD EVAL EM773 METER US PLUG
Manufacturer
NXP Semiconductors
Type
Other Power Managementr
Datasheets

Specifications of OM13005,598

Design Resources
Plug Meter Schematics, Gerber Files USB Dongle Schematics, Gerber Files
Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 32-Bit
Utilized Ic / Part
EM773FHN33,551
Interface Type
USB
Maximum Operating Temperature
+ 150 C
Operating Supply Voltage
1.8 V to 3.6 V
Product
Power Management Development Tools
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Primary Attributes
-
Secondary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
EM773, OL2381
Other names
568-6680
NXP Semiconductors
UM10415
User manual
16.5.2 Additional output for sinusoidal voltage and sinusoidal and
Apparent Power: S — The apparent power S in Volt-Ampere (VA) is measured as the
product of the RMS voltage and RMS current:
Active Power: P — The active power P in Watt (W) is measured according to:
Non-active Power: N — The non-active power N in Volt-Ampere-reactive (var) is
measured according to:
Power Factor: PF — The dimensionless parameter power factor PF is measured as the
ratio between active power and apparent power.
non-sinusoidal current
The Metrology Engine output described in this chapter provides additional information for
sinusoidal voltages and sinusoidal or non-sinusoidal currents.
According to IEEE Std 1459-2010 these calculations are valid if the voltage waveform has
significantly lower distortion than the current waveform. In this case the fundamental
active power P1 approximately equals the active power P described above.
Fundamental Reactive Power: Q1 — The fundamental reactive power in
Volt-Ampere-reactive (var) is measured according to:
In this formula, k is the index of the fundamental voltage samples v1 and fundamental
current samples i1 inside the Metrology Engine and T is the sample period of the
Metrology Engine.
All information provided in this document is subject to legal disclaimers.
Rev. 1 — 10 September 2010
Q
1
=
P
N
kT
=
ω
=
PF =
S =
kT
τ
1
+
∫ ∫
τ
S
kT
τ
VI
i
2
1
+
τ
[
P
S
kT
vidt
v
P
Chapter 16: EM773 Metrology engine
1
2
dt
]
dt
UM10415
© NXP B.V. 2010. All rights reserved.
190 of 310
(10)
(11)
(7)
(8)
(9)

Related parts for OM13005,598