OM13005,598 NXP Semiconductors, OM13005,598 Datasheet - Page 197

BOARD EVAL EM773 METER US PLUG

OM13005,598

Manufacturer Part Number
OM13005,598
Description
BOARD EVAL EM773 METER US PLUG
Manufacturer
NXP Semiconductors
Type
Other Power Managementr
Datasheets

Specifications of OM13005,598

Design Resources
Plug Meter Schematics, Gerber Files USB Dongle Schematics, Gerber Files
Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 32-Bit
Utilized Ic / Part
EM773FHN33,551
Interface Type
USB
Maximum Operating Temperature
+ 150 C
Operating Supply Voltage
1.8 V to 3.6 V
Product
Power Management Development Tools
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Primary Attributes
-
Secondary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
EM773, OL2381
Other names
568-6680
17.1 How to read this chapter
17.2 Metrology driver interface
UM10415
User manual
17.2.1 Metrology Engine initialization
17.2.2 Metrology Engine interrupt handler
17.2.3 Metrology Engine set ranges
The EM773 Metrology Engine is available on part EM773 only.
The following seven interfaces of the metrology firmware are exposed to the user
application:
This interface must be called by the application software before the metrology engine can
be used.
This interface configures the metrology engine with the proper settings based on the given
AHB system frequency and mains frequency.
The user application must add the metrology engine interrupt handler to the interrupt
vector table. The driver interrupt handler takes appropriate action according the measured
data and the configured ranges.
This interface must be called by the application software after the metrology engine is
initialized and before the metrology engine is started.
This interface sets the ranges for the voltage input and the current inputs.
The ranges are:
1. metrology engine initialization
2. metrology engine interrupt handler
3. metrology engine set ranges
4. metrology engine start
5. metrology engine stop
6. metrology engine read data
7. metrology engine get gain channel
UM10415
Chapter 17: EM773 Metrology engine interface
Rev. 1 — 10 September 2010
Vpp for the VOLTAGE input
I1pp for the I_HIGHGAIN input
I2pp for the I_LOWGAIN input
DeltaPhi1 for the I_HIGHGAIN input
DeltaPhi2 for the I_LOWGAIN input