OM13006,598 NXP Semiconductors, OM13006,598 Datasheet - Page 239

BOARD EVAL EM773 METER EU PLUG

OM13006,598

Manufacturer Part Number
OM13006,598
Description
BOARD EVAL EM773 METER EU PLUG
Manufacturer
NXP Semiconductors
Type
Other Power Managementr
Datasheets

Specifications of OM13006,598

Design Resources
Plug Meter Schematics, Gerber Files USB Dongle Schematics, Gerber Files
Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 32-Bit
Utilized Ic / Part
EM773FHN33,551
Interface Type
USB
Maximum Operating Temperature
+ 150 C
Operating Supply Voltage
1.8 V to 3.6 V
Product
Power Management Development Tools
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Primary Attributes
-
Secondary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
EM773, OL2381
Other names
568-6681
NXP Semiconductors
UM10415
User manual
20.3.3.3 Exception handlers
20.3.3.4 Vector table
Table 225. Properties of different exception types
[1]
[2]
[3]
[4]
For an asynchronous exception, other than reset, the processor can execute additional
instructions between when the exception is triggered and when the processor enters the
exception handler.
Privileged software can disable the exceptions that
configurable priority, see
For more information about HardFaults, see
The processor handles exceptions using:
Interrupt Service Routines (ISRs) — Interrupts IRQ0 to IRQ31 are the exceptions
handled by ISRs.
Fault handler — HardFault is the only exception handled by the fault handler.
System handlers — NMI, PendSV, SVCall SysTick, and HardFault are all system
exceptions handled by system handlers.
The vector table contains the reset value of the stack pointer, and the start addresses,
also called exception vectors, for all exception handlers.
the exception vectors in the vector table. The least-significant bit of each vector must be 1,
indicating that the exception handler is written in Thumb code.
Exception
number
12-13
14
15
16 and above
To simplify the software layer, the CMSIS only uses IRQ numbers and therefore uses negative values for
exceptions other than interrupts. The IPSR returns the Exception number, see
See
See
Increasing in steps of 4.
Section 20.3.3.4
Section
[1]
20–20.5.2.6.
All information provided in this document is subject to legal disclaimers.
IRQ
number
-
-2
-1
0 and above
Rev. 1 — 10 September 2010
for more information.
Section
[1]
Chapter 20: Appendix EM773 ARM Cortex-M0 reference
20–20.5.2.3.
Exception
type
Reserved
PendSV
SysTick
Interrupt (IRQ)
Section
…continued
Table 20–225
20–20.3.4.
Priority
-
Configurable
Configurable
Configurable
Figure 20–58
shows as having
[3]
[3]
[3]
Table
UM10415
shows the order of
© NXP B.V. 2010. All rights reserved.
20–220.
Vector
address
-
0x00000038
0x0000003C
0x00000040 and
above
[4]
[2]
239 of 310