Z16C3516VSG Zilog, Z16C3516VSG Datasheet - Page 259

IC 16MHZ Z8500 CMOS ISCC 68-PLCC

Z16C3516VSG

Manufacturer Part Number
Z16C3516VSG
Description
IC 16MHZ Z8500 CMOS ISCC 68-PLCC
Manufacturer
Zilog
Series
IUSC™r
Datasheets

Specifications of Z16C3516VSG

Controller Type
Serial Communications Controller (SCC)
Interface
USB
Voltage - Supply
4.75 V ~ 5.25 V
Current - Supply
50mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
68-LCC (J-Lead)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
269-4690-5
Z16C3516VSG

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z16C3516VSG
Manufacturer:
INTEL
Quantity:
6 219
Part Number:
Z16C3516VSG
Manufacturer:
Zilog
Quantity:
10 000
UM011001-0601
BUS DATA TRANSFERS
All data transfers to and from the ISCC™ are done in bytes
regardless of whether data occupies the lower or upper
byte of the 16-bit bus. Bus transfers as a slave peripheral
are done differently from bus transfers when the ISCC is
the bus master during DMA transactions. The ISCC is
fundamentally an 8-bit peripheral but supports 16-bit
buses in the DMA mode. Slave peripheral and DMA
transactions appear in the next sections.
Data Bus Transfers as a Slave Peripheral
When accessed as a peripheral device (when the ISCC is
not a bus master performing DMA transfers), only 8 bits
transfer. During ISCC register read, the byte data present
on the lower 8 bits of the bus is replicated on the upper 8
bits of the bus. Data is accepted by the ISCC only on the
lower 8 bits of the bus.
Write Register 0 (non-multiplexed bus mode)
D7
0
0
1
1
* With Point High Command
Figure 1. Write Register 0 Bit Functions
D6
0
1
0
1
D5 D4 D3 D2 D1 D0
0
0
0
0
1
1
1
1
Null Code
Reset Rx CRC Checker
Reset Tx CRC Generator
Reset Tx Underrun/EOM Latch
(Non-Multiplexed Bus Mode)
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
Null Code
Point High
Reset Ext/Status Interrupts
Send Abort (SDLC)
Enable Int on Next Rx Character
Reset Tx Int Pending
Error Reset
Reset Highest IUS
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Register 0
Register 1
Register 2
Register 3
Register 4
Register 5
Register 6
Register 7
Register 8
Register 9
Register 10
Register 11
Register 12
Register 13
Register 14
Register 15
*
0
0
0
0
nnel Only
Null Code
Reset Rx CRC Checker
Reset Tx CRC Generator
Reset Tx Underrun/EOM Latch
5 D4 D3 D2 D1 D0
ster 0 (multiplexed bus mode)
ISCC
During DMA transfers, when the ISCC is bus master, only
byte data transfers occur. However, data transfers to or
from the ISCC on the upper 8 bits of the bus or on the lower
8 bits of the bus. Moreover, odd or even byte transfers
activate on the lower or upper 8 bits of the bus. This is
programmable and explained next.
During DMA transfers to memory from the ISCC, only byte
data transfers occur. Data appears on the lower 8 bits and
replicates on the upper 8 bits of the bus. Thus, the data is
written to an odd or even byte of the system memory by
address decoding and strobe generation.
During DMA transfers to the ISCC from memory, byte data
only transfers. Normally, data appears only on the lower 8
bits of the bus. However, the byte swapping feature
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
Figure 2. Write Register 0 Bit Functions
DMA Bus Transfers
Interfacing the ISCC™ to the 68000 and 8086
Null Code
Null Code
Reset Ext/Status Interrupts
Send Abort
Enable Int on Next Rx Character
Reset Tx Int Pending
Error Reset
Reset Highest IUS
0
0
1
1
(Multiplexed Bus Mode)
0
1
0
1
Null Code
Null Code
Select Shift Left Mode
Select Shift Right Mode
0
Application Note
*
16-3

Related parts for Z16C3516VSG