Safety Precautions
• Outputs may remain ON due to a malfunction in the built-in transistor out-
• Part of the DM Area (data memory) in the Motion Control Module is held
• Part of the DM Area in the Coordinator Module is backed up in the built-in
• Confirm that no adverse effect will occur in the system before attempting
• Install external breakers and take other safety measures against short-cir-
• Be sure that all the terminal screws and cable connector screws are tight-
• Mount the Modules only after checking the connectors and terminal
• Before touching the Module, be sure to first touch a grounded metallic
• Be sure that the terminal blocks, connectors, and other items with locking
• Wire correctly according to the specified procedures.
• Always use the power supply voltage specified in the operation manuals.
• Take appropriate measures to ensure that the specified power with the
• Leave the dust protective label attached to the Module when wiring.
• Remove the dust protective label after the completion of wiring to ensure
• Use crimp terminals for wiring. Do not connect bare stranded wires
• Do not apply voltages to the built-in inputs in excess of the rated input
puts or other internal circuits. As a countermeasure for such problems,
external safety measures must be provided to ensure the safety of the
system.
using the super capacitor. Corrupted memory may prevent the correct
values from being saved, however. Take appropriate measures in the lad-
der program whenever the Memory Not Held Flag (A404.14) turns ON,
such as resetting the data in the DM Area.
flash memory when transferring data from the CX-Programmer. Do not
turn OFF the power to the FQM1 while data is being transferred. The data
will not be backed up if the power is turned OFF.
any of the following. Not doing so may result in an unexpected operation.
cuiting in external wiring. Insufficient safety measures against short-cir-
cuiting may result in burning.
ened to the torque specified in the relevant manuals. Incorrect tightening
torque may result in malfunction.
blocks completely.
object in order to discharge any static built-up. Not doing so may result in
malfunction or damage.
devices are properly locked into place. Improper locking may result in
malfunction.
An incorrect voltage may result in malfunction or burning.
rated voltage and frequency is supplied. Be particularly careful in places
where the power supply is unstable. An incorrect power supply may result
in malfunction.
Removing the label may result in malfunction.
proper heat dissipation. Leaving the label attached may result in malfunc-
tion.
directly to terminals. Connection of bare stranded wires may result in
burning.
voltage. Excess voltages may result in burning.
• Changing the operating mode of the FQM1
• Force-setting/force-resetting any bit in memory
• Changing the present value of any word or any set value in memory
xvii
3