XW2Z-200J-B1 Omron, XW2Z-200J-B1 Datasheet - Page 199

no-image

XW2Z-200J-B1

Manufacturer Part Number
XW2Z-200J-B1
Description
CONNECTOR CABLE 2M
Manufacturer
Omron
Datasheet

Specifications of XW2Z-200J-B1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z200JB1
Pulse Outputs
7-6-7
176
One-shot Pulse Output Function
Formula:
Actual frequency = Clock frequency ÷ INT (clock frequency/target frequency)
The difference between the target frequency and the actual frequency
increases at higher frequencies. The following tables shows examples for a
clock frequency of 20 MHz.
The one-shot pulse output function turns ON the output only for a specified
time between 0.01 and 9,999 ms. Use the STIM(980) instruction to start the
pulse output (turn the output from OFF to ON). After the time specified in
STIM(980) has elapsed, the pulse output is automatically turned OFF (in the
hardware).
Clock-generated pulses
(one of four possible settings)
Target frequency (Hz)
952,382 to 1,000,000
Note INT (clock frequency/target frequency) is the dividing ratio.
909,092 to 952,381
869,566 to 909,091
487,806 to 500,000
476,191 to 487,805
465,117 to 476,190
198,021 to 200,000
196,079 to 198,020
194,176 to 196,078
49,876 to 50,000
49,752 to 49,875
4,929 to 49,751
402
401
400
.
.
.
.
.
.
.
.
.
.
.
.
Actual output frequency
Integer dividing ratio set
according to the target
frequency set by user.
Dividing circuit
1,000,000
952,381
909,091
500,000
487,805
476,190
100,806
198,020
196,078
50,000
49,875
49,751
402
401
400
.
.
.
.
.
.
.
.
.
.
.
.
(Actual output frequency)
Output pulses
Section 7-6