System Setup in Motion Control Modules
Settings Used by All Motion Control Modules
CX-Programmer: Module Settings Tab Page
CX-Programmer: Cycle Time Tab Page
CX-Programmer: Other Tab Page
These settings are reserved for future expansion of Motion Control Module functionality.
System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations
+304
+305
+306
+307
+308
Address
Address
00
08
12
00 to 03 Interrupt Input Settings, Input 0 (CIO
04 to 07 Interrupt Input Settings, Input 1 (CIO
08 to 11 Interrupt Input Settings, Input 2 (CIO
12 to 15 Interrupt Input Settings, Input 3 (CIO
00 to 07 Select Synchro-
08 to 15
00 to 15 Cycle time
00 to 15 Watch cycle time
Bits
Bits
Allow writing to user memory (user
memory protection)
Prohibit system interruption of the sync
mode
Detect cycle time over warming (detec-
tion of cycle times longer than 10 ms)
0000.00) function
0000.01) function
0000.02) function
0000.03) function
nous Data
Function
Function
Upper 2 words (+0
and +1)
Lower 2 words (+2
and +3)
0 hex: Writing enabled
1 hex: Writing disabled
Note Set this bit to 1 to disable writing the fol-
lowing areas from the CX-Programmer: user
program and System Setup
0 hex: Allow interrupts
1 hex: Prohibit interrupts
Set this bit to 1 to prohibit system interrupts
during program execution and I/O memory
refreshing to maintain synced operation
between Modules in Sync Mode.
0 hex: Detect long cycles
1 hex: Do not detect long cycles
Note CIO 0105.09 will turn ON if this bit is set
to 0 and the cycle time exceeds 10 ms.
0 hex: Normal
1 hex: Interrupt input (at rising edge)
2 hex: Interrupt input (at falling edge)
3 hex: Interrupt input (at both edges)
Note Interrupt input settings of 1 to 3 hex
apply to input interrupt mode and counter
mode.
00 hex: Normal (via Ladder)
01 hex: High-speed counter PV (Counter 1 val-
ues)
02 hex: High-speed counter PV (Counter 2 val-
ues)
03 hex: Pulse output 1 PV
04 hex: Pulse output 2 PV
05 hex: Analog input
06 hex: Reserved
07 hex: Analog output 1 value
08 hex: Analog output 2 value
09 hex: Built-in input value (Inner I/O input)
5A hex: No data
0000 hex: Variable cycle time
0001 to 03E8 hex: Constant (minimum) cycle
time of 0.1 to 100.0 ms (unit: 0.1 ms)
If the actual cycle time is less than this setting,
it will be extended until this time passes.
Note A404.05 will turn ON if the minimum
cycle time set here is exceeded.
Change this setting only when you want to
change the default maximum cycle time. The
Cycle Time Too Long Flag (A401.08) will be
turned ON if the actual cycle time exceeds this
setting.
Remarks
Remarks
When disabling: At
power ON or at start of
operation
When enabling: When
changed
At power ON
At start of operation
At power ON
At start of operation
At start of operation
When setting is read
When setting is read
Appendix C