peb22504 Infineon Technologies Corporation, peb22504 Datasheet - Page 67
peb22504
Manufacturer Part Number
peb22504
Description
Quad Line Interface Unit For E1dt1dj1 Quadliu
Manufacturer
Infineon Technologies Corporation
Datasheet
1.PEB22504.pdf
(128 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
peb22504H
Manufacturer:
infineon
Quantity:
2 300
Company:
Part Number:
peb22504HT
Manufacturer:
Infineon
Quantity:
7
Company:
Part Number:
peb22504HT
Manufacturer:
INF
Quantity:
5 510
Company:
Part Number:
peb22504HT
Manufacturer:
SUNLORD
Quantity:
5 510
Company:
Part Number:
peb22504HT V1.1
Manufacturer:
Infineon
Quantity:
784
Company:
Part Number:
peb22504HT-V11
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
peb22504HTV1.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
RD(1:0)
Line Interface Mode 3 (Read/Write)
Addresses: 04
Value after reset: 00
LIM3
LBO(2:1)
GTP
MTP
Data Sheet
LBO2
7
H
, 24
Select Receive Data Output
These bits select the different stages of the received data path.
00 = Received data is decoded (HDB3/B8ZS/AMI) and output on
01 = Data recovered by the DPLL (not decoded) is output on
10 = Sliced data is transferred directly to RDOP/N.
11 = Sliced data is directly transferred to RDOP/N and the bypassed
Line Build-Out (T1 mode only)
In long-haul applications, LIM1.EQON = 1, a transmit filter can be
optionally placed in the transmit path to attenuate the signal level on
pins XL1/2. Selecting the transmitter attenuation is possible in steps
of 7.5 dB at 772kHz, which meets FCC Part 68 and ANSI T1.403.
To meet the line build-out characteristics defined by ANSI T1.403,
registers XPM(2:0) should be programmed as follows:
00 = 0 dB
01 = -7.5 dB -->XPM(0:2) = 11
10 = -15 dB -->XPM(0:2) = 8E
11 = -22.5 dB -->XPM(0:2) = 09
PRBS/IBL Generator in Transmit Path
0 =
1 =
PRBS/IBL Monitor in Transmit Path
0 =
1 =
LBO1
H
H
, 44
RDOP/N.
RDOP/N.
receive path logic is switched off to reduce power consumption
unless remote loop is activated.
The PRBS/IBL generator is placed in the receive path.
The PRBS/IBL generator is placed in the transmit path.
The PRBS/IBL monitor is placed in the receive path.
The PRBS/IBL monitor is placed in the transmit path.
H
, 64
GTP
H
MTP
67
EPRM
H
H
H
, 01
, 02
XPRBS
, 01
H
H
H
, 20
, 20
, 20
H
H
IPRBS
H
Register Description
QuadLIU V1.1
SPRBS
0
PEB 22504
2001-02