peb22504 Infineon Technologies Corporation, peb22504 Datasheet - Page 79

no-image

peb22504

Manufacturer Part Number
peb22504
Description
Quad Line Interface Unit For E1dt1dj1 Quadliu
Manufacturer
Infineon Technologies Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
peb22504H
Manufacturer:
infineon
Quantity:
2 300
Part Number:
peb22504HT
Manufacturer:
Infineon
Quantity:
7
Part Number:
peb22504HT
Manufacturer:
INF
Quantity:
5 510
Part Number:
peb22504HT
Manufacturer:
SUNLORD
Quantity:
5 510
Part Number:
peb22504HT V1.1
Manufacturer:
Infineon
Quantity:
784
Part Number:
peb22504HT-V11
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
peb22504HTV1.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Pulse Count Detection Register (Read/Write)
Addresses: 0C
Value after reset: C0
PCD
PCD(7:0)
Pulse Count Recovery (Read/Write)
Addresses: 0D
Value after reset: 18
PCR
PCR(7:0)
Data Sheet
PCD7
PCR7
7
7
H
H
, 2C
, 2D
Pulse Count Detection
An LOS alarm is detected if the incoming data stream has no
transitions for a programmable number T of consecutive pulse
positions. The number T is programmable via the PCD register and
can be calculated as follows:
T = 16
The maximum time is 256
256
resets the internal pulse counter. The counter is clocked with the
receive clock RCLK.
An LOS alarm is cleared if a pulse-density is detected in the received
bit stream. The number of pulses M which must occur in the
predefined PCD time interval is programmable via the PCR register,
and can be calculated as follows:
M = N + 1 ; with 0
The time interval starts with the first detected pulse transition. With
every received pulse, a counter is incremented and the actual counter
is compared with the contents of PCR register. If the pulse number is
greater or equal to the PCR value, the LOS alarm is reset. Otherwise
the alarm stays active. In this case, the next detected pulse transition
starts a new time interval.
Pulse Count Recovery
H
H
H
H
, 4C
, 4D
16
H
H
, 6C
, 6D
(PCD+1) ; with 0
648 ns = 2.65 ms in T1 mode. Every detected pulse
H
H
N
79
255.
PCD
16
255.
488 ns = 2 ms in E1 mode, or
Register Description
QuadLIU V1.1
PCD0
PCR0
0
0
PEB 22504
2001-02

Related parts for peb22504