ia186em Innovasic Semiconductor Inc., ia186em Datasheet - Page 38

no-image

ia186em

Manufacturer Part Number
ia186em
Description
8-bit/16-bit Microcontrollers
Manufacturer
Innovasic Semiconductor Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ia186em-PQF100I-R-03
Manufacturer:
INNOVASIC
Quantity:
3 590
Part Number:
ia186em-PQF100I-R-03
Manufacturer:
Innovasic Semiconductor
Quantity:
10 000
Part Number:
ia186em-PTQ100I-R-03
Manufacturer:
Innovasic Semiconductor
Quantity:
10 000
IA186EM/IA188EM
8-Bit/16-Bit Microcontrollers
2.2.33 s2_n–s0_n—Bus Cycle Status (synchronous outputs with tristate)
These three signals inform the system of the type of bus cycle in progress. The s2_n may be
used to indicate whether the current access is to memory or I/O, and s1_n may be used to
indicate whether data is being transmitted or received. These signals are tristated during bus
hold and hold acknowledge. The coding for these pins is presented in Table 10.
Table 10. Bus Cycle Types for s2_n, s1_n, and s0_n
2.2.34 s6/clkdiv2_n/pio29—Bus Cycle Status Bit 6 (synchronous output)/Clock Divide
The s6 signal is high during the second and remaining cycle periods (i.e., t
DMA-initiated bus cycle is underway. The s6 is tristated during bus hold or reset.
If the clkdiv2_n signal is held low during power-on-reset, the microcontroller enters clock
divide-by-2 mode. In this mode, the PLL is disabled and the processor receives the external
clock divided by 2. Sampling of this pin occurs on the rising edge of res_n.
Because this pin has an internal pull-up, it is not necessary to drive the pin high even though it
defaults to an input PIO.
2.2.35 sclk—Serial Clock (synchronous outputs with tristate)
Because this pin provides a slave device with a synchronous serial clock it permits
synchronization of the transmit and receive data exchanges between the slave and the
microcontroller. The sclk is the result of dividing the internal clock by 2, 4, 8, or 16, depending
on the contents of the Synchronous Serial Control (SSC) register Bits [5–4]. Accessing either
the SSR or SSD registers activates the sclk for eight cycles. When sclk is not active, the
microcontroller hold is high.
s2_n
0
0
0
0
1
1
1
1
Note: If this pin is used as pio29 and configured as an input, care should be
taken that it is not driven low during POR.
s1_n
by 2 (input with internal pull-up)
0
0
1
1
0
0
1
1
s0_n
0
1
0
1
0
1
0
1
®
Bus Cycle
Interrupt acknowledge
Read data from I/O
Write data to I/O
Halt
Instruction fetch
Read data from memory
Write data to memory
None (passive)
UNCONTROLLED WHEN PRINTED OR COPIED
Page 38 of 145
IA211050831-16
2
– t
4)
December 24, 2008
http://www.Innovasic.com
, indicating that a
Customer Support:
Data Sheet
1-888-824-4184

Related parts for ia186em