Datasheet
7.9.1.1
7.9.2
7.9.2.1
32099D–06/2010
31
23
15
7
-
-
-
-
First Word of the User Page (Address 0x80800000)
Default Fuse Value
Default user page first word value
30
22
14
6
-
-
-
-
The devices are shipped with the FGPFRLO register value: 0xE075FFFF:
After the JTAG or aWire chip erase command, the FGPFR register value is 0xFFFFFFFF.
WDTAUTO: WatchDog Timer Auto Enable at Startup
0: The WDT is automatically enabled at startup.
1: The WDT is not automatically enabled at startup.
Please refer to the WDT chapter for detail about timeout settings when the WDT is automatically
enabled.
The devices are shipped with the User page erased (all bits 1):
• BODEN fuses set to 11. BOD is disabled.
• BODHYST fuse set to 1. The BOD hysteresis is enabled.
• BODLEVEL fuses set to 000000. This is the minimum voltage trigger level for BOD.
• UPROT fuse set to 1.
• SECURE fuse set to 11.
• BOOTPROT fuses set to 010. The bootloader protected size is 8KBytes.
• EPFL fuse set to 1. External privileged fetch is not locked.
• LOCK fuses set to 1111111111111111. No region locked.
• WDTAUTO set to 1, WDT disabled.