EP9312-CB Cirrus Logic Inc, EP9312-CB Datasheet - Page 586

System-on-Chip Processor

EP9312-CB

Manufacturer Part Number
EP9312-CB
Description
System-on-Chip Processor
Manufacturer
Cirrus Logic Inc
Series
EP9r
Datasheets

Specifications of EP9312-CB

Peak Reflow Compatible (260 C)
No
A/d Converter
12 Bits
Leaded Process Compatible
No
No. Of I/o Pins
65
Package / Case
352-BGA
Core Processor
ARM9
Core Size
16/32-Bit
Speed
200MHz
Connectivity
EBI/EMI, EIDE, Ethernet, I²C, IrDA, Keypad/Touchscreen, SPI, UART/USART, USB
Peripherals
AC'97, DMA, I&sup2:S, LCD, LED, MaverickKey, POR, PWM, WDT
Number Of I /o
16
Program Memory Type
ROMless
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.65 V ~ 3.6 V
Data Converters
A/D 8x12b
Oscillator Type
External
Operating Temperature
0°C ~ 70°C
Processor Series
EP93xx
Core
ARM920T
Data Bus Width
32 bit
3rd Party Development Tools
MDK-ARM, RL-ARM, ULINK2
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-
Lead Free Status / Rohs Status
No
Other names
598-1257

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP9312-CB
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
Part Number:
EP9312-CB
Manufacturer:
CIRRUS
Quantity:
20 000
Part Number:
EP9312-CBZ
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
16
UART3IntIDIntClr
16-10
UART3 With HDLC Encoder
EP93xx User’s Guide
31
15
Address:
Default:
Definition:
Bit Descriptions:
30
14
29
13
28
12
BUSY:
DCD:
DSR:
CTS:
0x808E_001C - Read/Write
0x0000_0000
UART3 Interrupt Identification and Interrupt Clear Register. Interrupt status is
read from UART3IntIDIntClr. A write to UART3IntIDIntClr clears the modem
status interrupt. All the bits are cleared to “0” when reset.
RSVD:
RTIS:
27
11
26
10
RSVD
Copyright 2007 Cirrus Logic
25
9
UART Busy. If this bit is set to 1, the UART is busy
transmitting data. This bit remains set until the complete
byte, including all the stop bits, has been sent from the
shift register. This bit is set as soon as the transmit FIFO
becomes non-empty, regardless of whether the UART is
enabled or not.
Data Carrier Detect status. This bit is the complement of
the UART data carrier detect (nUARTDCD) modem status
input. That is, the bit is 1 when the modem status input is
0.
Data Set Ready status. This bit is the complement of the
UART data set ready (nUARTDSR) modem status input.
That is, the bit is 1 when the modem status input is 0.
Clear To Send status. This bit is the complement of the
UART clear to send (nUARTCTS) modem status input.
That is, the bit is 1 when the modem status input is 0.
Reserved. Unknown During Read.
Receive Timeout Interrupt Status. This bit is set to 1 if the
receive timeout interrupt is asserted. This bit is cleared
when the receive FIFO is empty or the receive line goes
active.
24
8
RSVD
23
7
22
6
21
5
20
4
RTIS
19
3
TIS
18
2
RIS
17
1
DS785UM1
MIS
16
0

Related parts for EP9312-CB