IDT82P2282PF IDT, Integrated Device Technology Inc, IDT82P2282PF Datasheet - Page 176

no-image

IDT82P2282PF

Manufacturer Part Number
IDT82P2282PF
Description
TXRX T1/J1/E1 2CHAN 100-TQFP
Manufacturer
IDT, Integrated Device Technology Inc
Type
Transceiverr
Datasheet

Specifications of IDT82P2282PF

Number Of Drivers/receivers
2/2
Protocol
IEEE 1149.1
Voltage - Supply
3 V ~ 3.6 V
Mounting Type
Surface Mount
Package / Case
100-TQFP, 100-VQFP
Screening Level
Industrial
Pin Count
100
Mounting
Surface Mount
Package Type
TQFP
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
82P2282PF

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDT82P2282PF
Manufacturer:
IDT
Quantity:
355
Part Number:
IDT82P2282PF
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82P2282PF8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82P2282PFG
Manufacturer:
HITACHI
Quantity:
1 452
Part Number:
IDT82P2282PFG
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82P2282PFG8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
T1/J1 XDL2 (067H, 167H)
S[4:1]:
the data to replace the Switch (S) bit. The S[1] is transmitted first.
A[2:1]:
the data to replace the Alarm (A) bit. The A[1] is transmitted first.
T1/J1 FGEN Maintenance 0 (06BH, 16BH)
AUTOYELLOW:
stream.
XYEL:
Programming Information
IDT82P2282
Bit Name
Bit Name
Default
Default
Bit No.
Bit No.
Type
Type
These bits are valid in SLC-96 format when the FDIS bit (b0, T1/J1-062H,...) and the FDLBYP bit (b2, T1/J1-062H,...) are both ‘0’s. They contain
These bits are valid in SLC-96 format when the FDIS bit (b0, T1/J1-062H,...) and the FDLBYP bit (b2, T1/J1-062H,...) are both ‘0’s. They contain
= 0: Disable the automatic Yellow alarm signal insertion.
= 1: The Yellow alarm signal is automatically inserted into the data stream to be transmitted when Red alarm is declared in the received data
= 0: Disable the manual Yellow alarm signal insertion.
= 1: The Yellow alarm signal is manually inserted into the data stream to be transmitted.
7
7
Reserved
6
6
S4
R
5
0
5
Reserved
S3
R
4
0
4
176
DUAL T1/E1/J1 LONG HAUL / SHORT HAUL TRANSCEIVER
S2
R
3
0
3
S1
R
2
0
2
AUTOYELLOW
R/W
A2
R
1
0
1
0
August 20, 2009
XYEL
R/W
A1
R
0
0
0
0