tmp88fw45afg TOSHIBA Semiconductor CORPORATION, tmp88fw45afg Datasheet - Page 97

no-image

tmp88fw45afg

Manufacturer Part Number
tmp88fw45afg
Description
8 Bit Microcontroller Tlcs-870/x Series
Manufacturer
TOSHIBA Semiconductor CORPORATION
Datasheet
Note 3: To set the mode, source clock, PPG output control and timer F/F control, write to TC1CR during TC1CR<TC1S>=00. Set
Note 4: Auto-capture can be used only in the timer, event counter, and window modes.
Note 5: To set the timer registers, the following relationship must be satisfied.
Note 6: Set TC1CR<TFF1> to “0” in the mode except PPG output mode.
Note 7: Set TC1DRB after setting TC1CR<TC1M> to the PPG output mode.
Note 8: When the STOP mode is entered, the start control (TC1CR<TC1S>) is cleared to “00” automatically, and the timer stops.
Note 9: Use the auto-capture function in the operative condition of TC1. A captured value may not be fixed if it's read after the
Note 10: Since the up-counter value is captured into TC1DRB by the source clock of up-counter after setting TC1CR<ACAP1> to
the timer F/F1 control until the first timer start after setting the PPG mode.
TC1DRA > TC1DRB > 1 (PPG output mode), TC1DRA > 1 (other modes)
After the STOP mode is exited, set the TC1CR<TC1S> to use the timer counter again.
execution of the timer stop or auto-capture disable. Read the capture value in a capture enabled condition.
"1". Therefore, to read the captured value, wait at least one cycle of the internal source clock before reading TC1DRB for
the first time.