UPD78F1201MC-CAB-AX Renesas Electronics America, UPD78F1201MC-CAB-AX Datasheet - Page 281

no-image

UPD78F1201MC-CAB-AX

Manufacturer Part Number
UPD78F1201MC-CAB-AX
Description
MCU 16BIT 78K0R/LX3 30-SSOP
Manufacturer
Renesas Electronics America
Series
78K0R/Ix3r
Datasheet

Specifications of UPD78F1201MC-CAB-AX

Core Processor
78K/0R
Core Size
16-Bit
Speed
40MHz
Connectivity
3-Wire SIO, I²C, LIN, UART/USART
Peripherals
DMA, LVD, POR, PWM, WDT
Number Of I /o
21
Program Memory Size
16KB (16K x 8)
Program Memory Type
FLASH
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 6x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
6.3 Registers Controlling Timer Array Unit TAUS
Timer array unit TAUS is controlled by the following registers.
• Peripheral enable register 2 (PER2)
• Timer clock select register 0 (TPS0)
• Timer mode register n (TMRn)
• Timer status register n (TSRn)
• Timer channel enable status register 0 (TE0)
• Timer channel start register 0 (TS0)
• Timer channel stop register 0 (TT0)
• Timer input select register 0 (TIS0)
• Timer output enable register 0 (TOE0)
• Timer output register 0 (TO0)
• Timer output level register 0 (TOL0)
• Timer output mode register 0 (TOM0)
• Timer triangle wave output mode register 0 (TOT0)
• Timer dead time output enable register 0 (TDE0)
• Timer real-time output register 0 (TRO0)
• Timer real-time output enable register 0 (TRE0)
• Timer real-time control register 0 (TRC0)
• Timer modulation output enable register 0 (TME0)
• TAU option mode register (OPMR)
• TAU option status register (OPSR)
• TAU option Hi-Z start trigger register (OPHS)
• TAU option Hi-Z stop trigger register (OPHT)
• TAU option control register (OPCR)
• Input switch control registers (ISC)
• Noise filter enable registers 1, 2 (NFEN1, NFEN2)
• Port mode registers 0, 1, 3, 5, 7 (PM0, PM1, PM3, PM5, PM7)
• Port registers 0, 1, 3, 5, 7 (P0, P1, P3, P5, P7)
Notes 1. This is not provided in the 78K0R/IB3.
Remark n = 00 to 11
2. registers are used with the inverter control function. For details, refer to CHAPTER 7 INVERTER
3. The PM0 and P0 registers are only provided in the 78K0R/ID3 and 78K0R/IE3. The PM7 and P7
CONTROL FUNCTIONS.
registers are not provided in 78K0R/IB3.
Note 2
Note 2
CHAPTER 6 TIMER ARRAY UNIT TAUS
Note 1
Note 2
Note 2
Note 2
User’s Manual U19678EJ1V1UD
Note 2
Note 2
Note3
Note 2
Note 2
Note 2
Note 2
Note3
279