UPD78F1201MC-CAB-AX Renesas Electronics America, UPD78F1201MC-CAB-AX Datasheet - Page 487

no-image

UPD78F1201MC-CAB-AX

Manufacturer Part Number
UPD78F1201MC-CAB-AX
Description
MCU 16BIT 78K0R/LX3 30-SSOP
Manufacturer
Renesas Electronics America
Series
78K0R/Ix3r
Datasheet

Specifications of UPD78F1201MC-CAB-AX

Core Processor
78K/0R
Core Size
16-Bit
Speed
40MHz
Connectivity
3-Wire SIO, I²C, LIN, UART/USART
Peripherals
DMA, LVD, POR, PWM, WDT
Number Of I /o
21
Program Memory Size
16KB (16K x 8)
Program Memory Type
FLASH
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 6x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Remark
Figure 7-84. Operation Procedure When Non-complementary Modulation Output Function (Type 1) Is Used (1/2)
TAUS
default
setting
Channel
default
setting
m = 02 to 07
Sets the TAU0EN and TAUOPEN bits of the PER2
register to 1.
Sets the TPS0 register.
Sets the TMR00, TMR01, and TMRm registers of eight
channels to be used (determines operation mode of
channels).
An interval (period) value is set to the TDR00 register of
the master channel, 0000H is set to the TDR01 register
of slave channel 1, and a duty factor is set to the TDRm
register of slave channel m.
Sets slave channel 1.
Sets slave channels 2 to 7.
Determines clock frequencies of CK00 and CK01.
Sets the TRC01 bit to 1 (trigger generation channel).
Sets the TOMm bit to 1 (slave channel output mode).
Sets the TOTm bit to 0 (generates other than
triangular wave PWM output).
Sets the TOLm bit and determines the active level of
the TOm output.
Sets the TDEm bit to 0 (stops dead time control).
Sets the TREm bit to 1 (real-time output enable).
Real-time output level is set to the TROm bit.
Sets the TRCm bit to 0 (non-trigger generation
channel).
Sets the TMEm bit and determines the modulated
output control.
Sets the TOm bit and determines default level of the
TOm output.
Sets the TOEm bit to 1 and enables operation of
TOm.
Clears the port register and port mode register to 0.
Software Operation
CHAPTER 7 INVERTER CONTROL FUNCTIONS
User’s Manual U19678EJ1V1UD
Power-off status
Power-on status. Each channel stops operating.
Channel stops operating.
(Clock is supplied and some power is consumed.)
The TOm pin goes into Hi-Z output state.
The TOm default setting level is output when the port mode
register is in output mode and the port register is 0.
TOm does not change because channel has stopped
operating.
The TOm pin outputs the TOm set level.
(Clock supply is stopped and writing to each register is
disabled.)
(Clock supply is started and writing to each register is
enabled.)
Hardware Status
485