UPD70F3763GC-UEU-AX Renesas Electronics America, UPD70F3763GC-UEU-AX Datasheet - Page 645

no-image

UPD70F3763GC-UEU-AX

Manufacturer Part Number
UPD70F3763GC-UEU-AX
Description
MCU 32BIT V850ES/JX3-U 100-LQFP
Manufacturer
Renesas Electronics America
Series
V850ES/Jx3-Ur
Datasheet

Specifications of UPD70F3763GC-UEU-AX

Core Processor
RISC
Core Size
32-Bit
Speed
48MHz
Connectivity
CSI, EBI/EMI, I²C, UART/USART, USB
Peripherals
DMA, LVD, PWM, WDT
Number Of I /o
75
Program Memory Size
384KB (384K x 8)
Program Memory Type
FLASH
Ram Size
48K x 8
Voltage - Supply (vcc/vdd)
2.85 V ~ 3.6 V
Data Converters
A/D 12x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD70F3763GC-UEU-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
V850ES/JG3-U, V850ES/JH3-U
R01UH0043EJ0300 Rev.3.00
Sep 30, 2010
(5) Sub-count register (RC1SUBC)
(6) Second count register (RC1SEC)
The RC1SUBC register is a 16-bit register that counts the reference time of 1 second of the real-time counter.
It takes a value of 0000H to 7FFFH and counts one second with a clock of 32.768 kHz.
This register is read-only, in 16-bit units.
Reset sets this register to 0000H.
Cautions 1 When a correction is made by using the RC1SUBU register, the value may become 8000H
The RC1SEC register is an 8-bit register that takes a value of 0 to 59 (decimal) and indicates the count value of
seconds.
It counts up when the sub-counter overflows.
When data is written to this register, it is written to a buffer and then to the counter up to 2 clocks (2 x 32.768 kHz)
later. Set a decimal value of 00 to 59 to this register in BCD code.
This register can be read or written in 8-bit units.
Reset sets this register to 00H.
Caution Setting the RC1SEC register to values other than 00 to 59 is prohibited.
Remark
RC1SUBC
RC1SEC
See 12.4.1 Initial settings, 12.4.2 Rewriting each counter during the real-time counter operation,
and 12.4.3 Reading each counter during the real-time counter operation when reading or writing the
RC1SEC register.
2. This register is also cleared by writing to the second count register.
3. The value read from this register is not guaranteed if it is read during operation, because a
After reset: 0000H
After reset: 00H
or more.
changing value is read.
15
0
14
13
R/W
R
12
11
Address:
Address: FFFFFAD2H
10
9
FFFFFAD0H
8
7
6
5
CHAPTER 12 REAL-TIME COUNTER
4
3
2
1
0
Page 645 of 1408