EP1AGX20CF484C6N Altera, EP1AGX20CF484C6N Datasheet - Page 229

IC ARRIA GX FPGA 20K 484FBGA

EP1AGX20CF484C6N

Manufacturer Part Number
EP1AGX20CF484C6N
Description
IC ARRIA GX FPGA 20K 484FBGA
Manufacturer
Altera
Series
Arria GXr
Datasheet

Specifications of EP1AGX20CF484C6N

Number Of Logic Elements/cells
21580
Number Of Labs/clbs
1079
Total Ram Bits
1229184
Number Of I /o
230
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
484-FBGA
Family Name
Arria™ GX
Number Of Logic Blocks/elements
21580
# I/os (max)
230
Process Technology
CMOS
Operating Supply Voltage (typ)
1.2V
Logic Cells
21580
Ram Bits
1229184
Operating Supply Voltage (min)
1.15V
Operating Supply Voltage (max)
1.25V
Operating Temp Range
0C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
484
Package Type
FC-FBGA
No. Of Macrocells
21580
Family Type
Arria GX
No. Of I/o's
230
Operating Frequency Max
622.08MHz
Operating Temperature Range
0°C To +85°C
Logic Case Style
BGA
No. Of Pins
484
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant
Other names
544-2395

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP1AGX20CF484C6N
Manufacturer:
ALTERA
Quantity:
672
Part Number:
EP1AGX20CF484C6N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1AGX20CF484C6N
Manufacturer:
ALTERA
Quantity:
8 000
Part Number:
EP1AGX20CF484C6N
Manufacturer:
ALTERA
0
Part Number:
EP1AGX20CF484C6N
Manufacturer:
ALTERA
Quantity:
40
Chapter 4: DC and Switching Characteristics
JTAG Timing Specifications
© December 2009 Altera Corporation
Table 4–123
Table 4–123. Arria GX JTAG Timing Parameters and Values
t
t
t
t
t
t
t
t
t
t
t
t
t
JCP
JCH
JCL
JPSU
JPH
JPCO
JPZX
JPXZ
JSSU
JSH
JSCO
JSZX
JSXZ
Symbol
TCK clock period
TCK clock high time
TCK clock low time
JTAG port setup time
JTAG port hold time
JTAG port clock to output
JTAG port high impedance to valid output
JTAG port valid output to high impedance
Capture register setup time
Capture register hold time
Update register clock to output
Update register high impedance to valid
output
Update register valid output to high
impedance
lists the JTAG timing parameters and values for Arria GX devices.
Parameter
Min
30
12
12
4
5
4
5
Arria GX Device Handbook, Volume 1
Max
12
12
12
9
9
9
Units
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
4–107

Related parts for EP1AGX20CF484C6N