TMPM364F10FG Toshiba, TMPM364F10FG Datasheet - Page 490

no-image

TMPM364F10FG

Manufacturer Part Number
TMPM364F10FG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMPM364F10FG

Product Summaries
Summary
Lead Free
Yes
Rohs Compatible Product(s)
Available
Rom (kbytes)
1024K
Rom Type
Flash
Ram (kbytes)
64K
Number Of Pins
144
Package
LQFP(20x20)
Vcc
3V
Cpu Mhz
64
Ssp (ch) Spi
1
I2c/sio (ch)
5
Uart/sio (ch)
12
Usb
Host
Can
1
Ethernet
-
External Bus Interface
Y
Cs/wait Controller (ch)
4
Dma Controller
2
10-bit Da Converter
-
10-bit Ad Converter
16
12-bit Ad Converter
-
16-bit Timer / Counter
16
Motor / Igbt Control
-
Real Time Clock
Y
Watchdog Timer
Y
Osc Freq Detect
-
Clock Gear
Y
Low-power Hold Function
Y
Remote Control Interface
Y
Hardware Cec Controller
Y
Comparators
-
Low-voltage Detector
-
Etm Hardware Trace
4-bit

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TMPM364F10FG
Manufacturer:
Toshiba
Quantity:
10 000
Company:
Part Number:
TMPM364F10FG
Quantity:
6 000
14.5
Control in the I2C Bus Mode
SCL (Line)
Internal SDA output (masterA)
Internal SDA output(master B)
SDA Line
"Low" level and Master B outputs the "High" level.
When the SCL line goes high at the point b, the slave device reads the SDA line data, i.e., data transmitted
by Master A. At this time, data transmitted by Master B becomes invalid.
fect the data transfer initiated by another master. If two or more masters have transmitted exactly the same
first data word, the arbitration procedure continues with the second data word.
If there is a difference between these two values, Arbitration Lost occurs and SBIxSR<AL> is set to "1".
ceiver.Therefore, the serial bus interface circuit stops the clock output during data transfer after <AL> is set
to "1".
Up until the point a, Master A and Master B output the same data. At the point a, Master A outputs the
Then Master A pulls the SDA bus line to the "Low" level because the line has the wired-AND connection.
This condition of Master B is called "Arbitration Lost". Master B releases its SDA pin, so that it does not af-
A master compares the SDA bus line level and the internal SDA output level at the rising of the SCL line.
When <AL> is set to "1", SBIxSR<MST, TRX> are cleared to "0", causing the SBI to operate as a slave re-
<AL> is cleared to "0" when data is written to or read from SBIxDBR or data is written to SBIxCR2.
Figure 14-7 Lost Arbitration
Page 464
a
b
Loses arbitration and sets the
internal SDA output to “1”.
TMPM364F10FG

Related parts for TMPM364F10FG