TMPM364F10FG Toshiba, TMPM364F10FG Datasheet - Page 654

no-image

TMPM364F10FG

Manufacturer Part Number
TMPM364F10FG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMPM364F10FG

Product Summaries
Summary
Lead Free
Yes
Rohs Compatible Product(s)
Available
Rom (kbytes)
1024K
Rom Type
Flash
Ram (kbytes)
64K
Number Of Pins
144
Package
LQFP(20x20)
Vcc
3V
Cpu Mhz
64
Ssp (ch) Spi
1
I2c/sio (ch)
5
Uart/sio (ch)
12
Usb
Host
Can
1
Ethernet
-
External Bus Interface
Y
Cs/wait Controller (ch)
4
Dma Controller
2
10-bit Da Converter
-
10-bit Ad Converter
16
12-bit Ad Converter
-
16-bit Timer / Counter
16
Motor / Igbt Control
-
Real Time Clock
Y
Watchdog Timer
Y
Osc Freq Detect
-
Clock Gear
Y
Low-power Hold Function
Y
Remote Control Interface
Y
Hardware Cec Controller
Y
Comparators
-
Low-voltage Detector
-
Etm Hardware Trace
4-bit

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TMPM364F10FG
Manufacturer:
Toshiba
Quantity:
10 000
Company:
Part Number:
TMPM364F10FG
Quantity:
6 000
18.6
Register
31-24
23-13
12
11
10
9
8
7-0
Bit
POTPGT[7:0]
NOCP
OCPM
DT
NPS
PSM
NDP[7:0]
Bit Symbol
R/W
R/W
R/W
R
R/W
R/W
R
(HCD)
Type
R
R
R
R
R
R
R
Type
(HC)
Filed name:Power On To Power Good Time
This byte specifies the duration HCD has to wait before accessing a powered-on port of the Root
Hub. It is implementation-specific. The unit of time is 2 ms. The duration is calculated as
POTPGT×2 ms.
Reserved
Filed name:No Over Current Protection
This bit describes how the overcurrent status for the Root Hub ports are reported. When this bit
is cleared, the OverCurrentProtectionMode field specifies global or per-port reporting.
0: Over-current status is reported collectively for all downstream ports.
1: No overcurrent protection supported.
Filed name:Over Current Protection Mode
This bit describes how the overcurrent status for the Root Hub ports are reported. At reset, this
fields should reflect the same mode as PowerSwitchingMode. This field is valid only if the NoOver-
CurrentProtection field is cleared.
0: Over-current status is reported collectively for all downstream ports.
1: Over-current status is reported on a per-port basis.
Device Type
This bit specifies that the Root Hub is not a compound device. The Root Hub is not permitted to
be a compound device. This field should always read/write 0.
Filed name:No Power Switching
These bits are used to specify whether power switching is supported or ports are always pow-
ered. It is implementation- specific. When this bit is cleared, the PowerSwitchingMode specifies glob-
al or per-port switching.
0: Ports are power switched.
1: Ports are always powered on when the HC is powered on.
Filed name:Power Switching Mode
This bit is used to specify how the power switching of the Root Hub ports is controlled. It is imple-
mentation-specific. This field is only valid if the NoPowerSwitching field is cleared.
0: All ports are powered at the same time.
1: Each port is powered individually. This mode allows port power to be controlled by either the glob-
al switch or per-port switching. If the PortPowerControlMask bit is set, the port responds only to
port power commands (Set/ClearPortPower). If the port mask is cleared, then the port is control-
led only by the global power switch (Set/ClearGlobalPower).
Filed name:Number Downstream Ports
These bits specify the number of downstream ports supported by the Root Hub. It is implementation-
specific. This module has one port, so "0x01" is read.
Page 628
Function
TMPM364F10FG

Related parts for TMPM364F10FG