upd78f0730 Renesas Electronics Corporation., upd78f0730 Datasheet - Page 279

no-image

upd78f0730

Manufacturer Part Number
upd78f0730
Description
8-bit Single-chip Microcontroller
Manufacturer
Renesas Electronics Corporation.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
upd78f0730MC(S)-CAB-AX/JM
Manufacturer:
NEC
Quantity:
538
Part Number:
upd78f0730MC(S)-CAB-AX/JM
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
upd78f0730MC(S)-CAB-AX/JM
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
upd78f0730MC-CAB-AX
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
(e) GET_STATUS() request
(f) SET_ADDRESS() request
A STALL response is made in the data stage if any of wValue, wIndex, or wLength is other than the values
shown in Table 12-3. A STALL response is also made in the data stage if the target is an interface or an
endpoint that does not exist.
• Default state:
• Addressed state: The value stored in the target status register
• Configured state: The value stored in the target status register
A STALL response is made in the status stage if either of wIndex or wLength is other than the values
shown in Table 12-3. A STALL response is also made if the specified device address is greater than 127.
• Default state:
• Addressed state: The device enters the Default state and returns the USB Address value to be input to
• Configured state: The device remains in the Configured state and returns the USB Address value to be
Note The target status register is as follows.
• If the target is a device: UF0 device status register L (UF0DSTL)
• If the target is endpoint 0: UF0 EP0 status register L (UF0E0SL)
• If the target is endpoint n: UF0 EPn status register L (UF0EnSL) (n = 1 to 2)
The value stored in the target status register
GET_STATUS() request has been received and when the request is for a device or
Endpoint0; otherwise a STALL response is made in the data stage.
GET_STATUS() request has been received and when the request is for a device or
Endpoint0; otherwise a STALL response is made in the data stage.
GET_STATUS() request has been received and when the request is for a device or an
endpoint that exists; otherwise a STALL response is made in the data stage.
The device enters the Addressed state and changes the USB Address value to be
input to SIE into a specified address value if the specified address is other than 0
when the SET_ADDRESS() request has been received. If the specified address is 0,
the device remains in the Default state.
SIE to the default address if the specified address is 0 when the SET_ADDRESS()
request has been received. If the specified address is other than 0, the device
remains in the Addressed state, and changes the USB Address value to be input to
SIE into a specified new address value.
input to SIE to the default address if the specified address is 0 when the
SET_ADDRESS() request has been received. In this case, the endpoints other than
endpoint 0 remain valid, and control transfer (IN), control transfer (OUT), bulk transfer
and interrupt transfer for an endpoint other than endpoint 0 are also acknowledged. If
the specified address is other than 0, the device remains in the Configured state and
changes the USB Address value to be input to SIE into a specified new address value.
CHAPTER 12 USB FUNCTION CONTROLLER (USBF)
Preliminary User’s Manual U19014EJ1V0UD
Note
Note
Note
is returned only when the
is returned only when the
is returned only when the
279