r4f2426 Renesas Electronics Corporation., r4f2426 Datasheet - Page 904

no-image

r4f2426

Manufacturer Part Number
r4f2426
Description
16-bit Single-chip Microcomputer H8s Family / H8s/2400 Series
Manufacturer
Renesas Electronics Corporation.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
r4f24268NVFQV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
r4f24268NVFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
r4f24268NVRFQV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
r4f24268NVRFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
r4f24268NVZFQV
Manufacturer:
REA
Quantity:
150
Part Number:
r4f24268NVZFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
r4f24269NVFQV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
r4f24269NVFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 15 Serial Communication Interface (SCI, IrDA)
15.4.6
Figure 15.8 shows an example of the operation for reception in asynchronous mode. In serial
reception, the SCI operates as described below.
1. The SCI monitors the communication line, and if a start bit is detected, performs internal
2. If an overrun error (when reception of the next data is completed while the RDRF flag is still
3. If a parity error is detected, the PER bit in SSR is set to 1 and receive data is transferred to
4. If a framing error (when the stop bit is 0) is detected, the FER bit in SSR is set to 1 and receive
5. If reception finishes successfully, the RDRF bit in SSR is set to 1, and receive data is
Rev. 1.00 Sep. 19, 2008 Page 876 of 1270
REJ09B0466-0100
RDRF
FER
synchronization, receives receive data in RSR, and checks the parity bit and stop bit.
set to 1) occurs, the ORER bit in SSR is set to 1. If the RIE bit in SCR is set to 1 at this time,
an ERI interrupt request is generated. Receive data is not transferred to RDR. The RDRF flag
remains to be set to 1.
RDR. If the RIE bit in SCR is set to 1 at this time, an ERI interrupt request is generated.
data is transferred to RDR. If the RIE bit in SCR is set to 1 at this time, an ERI interrupt
request is generated.
transferred to RDR. If the RIE bit in SCR is set to 1 at this time, an RXI interrupt request is
generated. Because the RXI interrupt routine reads the receive data transferred to RDR before
reception of the next receive data has finished, continuous reception can be enabled.
1
Serial Data Reception (Asynchronous Mode)
Start
bit
0
D0
Figure 15.8 Example of SCI Operation in Reception
(Example with 8-Bit Data, Parity, One Stop Bit)
D1
1 frame
Data
D7
Parity
bit
RXI interrupt
request
generated
0/1
Stop
bit
1
Start
bit
0
RDR data read and RDRF
flag cleared to 0 in RXI
interrupt handling routine
D0
D1
Data
D7
Parity
bit
ERI interrupt request
generated by framing
error
0/1
Stop
bit
0
Idle state
(mark state)
1

Related parts for r4f2426