MC68HC908AP16CFA MOTOROLA [Motorola, Inc], MC68HC908AP16CFA Datasheet - Page 303

no-image

MC68HC908AP16CFA

Manufacturer Part Number
MC68HC908AP16CFA
Description
Microcontrollers
Manufacturer
MOTOROLA [Motorola, Inc]
Datasheet
15.7.2 Mode Fault Error
MC68HC908AP Family — Rev. 2.5
MOTOROLA
Setting the SPMSTR bit selects master mode and configures the
SPSCK and MOSI pins as outputs and the MISO pin as an input.
Clearing SPMSTR selects slave mode and configures the SPSCK and
MOSI pins as inputs and the MISO pin as an output. The mode fault bit,
MODF, becomes set any time the state of the slave select pin, SS, is
inconsistent with the mode selected by SPMSTR.
To prevent SPI pin contention and damage to the MCU, a mode fault
error occurs if:
For the MODF flag to be set, the mode fault error enable bit (MODFEN)
must be set. Clearing the MODFEN bit does not clear the MODF flag but
does prevent MODF from being set again after MODF is cleared.
Figure 15-10. Clearing SPRF When OVRF Interrupt Is Not Enabled
SPI RECEIVE
COMPLETE
Freescale Semiconductor, Inc.
SPSCR
For More Information On This Product,
OVRF
READ
READ
SPDR
SPRF
The SS pin of a slave SPI goes high during a transmission
The SS pin of a master SPI goes low at any time
1
2
3
4
5
6
7
BYTE 1
Go to: www.freescale.com
BYTE 2 SETS SPRF BIT.
CPU READS SPSCR WITH SPRF BIT SET
AND OVRF BIT CLEAR.
BYTE 3 SETS OVRF BIT. BYTE 3 IS LOST.
BYTE 1 SETS SPRF BIT.
CPU READS SPSCR WITH SPRF BIT SET
AND OVRF BIT CLEAR.
CPU READS BYTE 1 IN SPDR,
CLEARING SPRF BIT.
CPU READS SPSCR AGAIN
TO CHECK OVRF BIT.
1
2
3
4
BYTE 2
5
BYTE 3
Serial Peripheral Interface Module (SPI)
6
7
8
10
11
12
13
14
8
9
CPU READS SPSCR AGAIN
TO CHECK OVRF BIT.
CPU READS BYTE 2 SPDR,
CLEARING OVRF BIT.
BYTE 4 SETS SPRF BIT.
CPU READS SPSCR.
CPU READS BYTE 4 IN SPDR,
CLEARING SPRF BIT.
CPU READS SPSCR AGAIN
TO CHECK OVRF BIT.
CPU READS BYTE 2 IN SPDR,
CLEARING SPRF BIT.
9
BYTE 4
10
11
12
Error Conditions
Data Sheet
13
14
303

Related parts for MC68HC908AP16CFA