HD6413008F RENESAS [Renesas Technology Corp], HD6413008F Datasheet - Page 403

no-image

HD6413008F

Manufacturer Part Number
HD6413008F
Description
Renesas 16-Bit Single-Chip Microcomputer H8 Family/H8/300H Series
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6413008F25
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6413008F25
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6413008F25V
Manufacturer:
MITSUMI
Quantity:
2 949
Part Number:
HD6413008F25V
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD6413008F25V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6413008FBL25
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6413008FBL25
Manufacturer:
HIT
Quantity:
9 676
• Receiving Serial Data (Asynchronous Mode): Figure 12.7 shows a sample flowchart for
receiving serial data and indicates the procedure to follow.
No
No
Read receive data from RDR, and
Read ORER, PER, and FER
clear RDRF flag to 0 in SSR
Clear RE bit to 0 in SCR
Read RDRF flag in SSR
PER∨FER∨OPER = 1
All data received?
Start receiving
flags in SSR
Figure 12.7 Sample Flowchart for Receiving Serial Data (1)
RDRF = 1
Initialize
<End>
Yes
Yes
No
(continued on next page)
Error handling
Yes
(5)
(1)
(2)
(4)
(3)
(2)(3)
(4)
(5)
(1)
SCI initialization:
the receive data input function of the RxD
pin is selected automatically.
Receive error handling and break detection:
if a receive error occurs, read the ORER,
PER, and FER flags in SSR to identify the
error. After executing the necessary error
handling, clear the ORER, PER, and FER
flags all to 0. Receiving cannot resume if
any of these flags remains set to 1. When a
framing error occurs, the RxD pin can be
read to detect the break state.
SCI status check and receive data read:
read SSR, check that the RDRF flag is set
to 1, then read receive data from RDR and
clear the RDRF flag to 0. Notification that
the RDRF flag has changed from 0 to 1 can
also be given by the RXI interrupt.
To continue receiving serial data:
check the RDRF flag, read RDR, and clear
the RDRF flag to 0 before the stop bit of the
current frame is received.
Rev.4.00 Aug. 20, 2007 Page 359 of 638
12. Serial Communication Interface
REJ09B0395-0400

Related parts for HD6413008F