HD6413008F RENESAS [Renesas Technology Corp], HD6413008F Datasheet - Page 463

no-image

HD6413008F

Manufacturer Part Number
HD6413008F
Description
Renesas 16-Bit Single-Chip Microcomputer H8 Family/H8/300H Series
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6413008F25
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6413008F25
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6413008F25V
Manufacturer:
MITSUMI
Quantity:
2 949
Part Number:
HD6413008F25V
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD6413008F25V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6413008FBL25
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6413008FBL25
Manufacturer:
HIT
Quantity:
9 676
Bit 7—Trigger Enable (TRGE): Enables or disables starting of A/D conversion by an external
trigger or 8-bit timer compare match.
External trigger pin and 8-bit timer selection is performed by the 8-bit timer. For details, see
section 9, 8-Bit Timers.
Bits 6 to 1—Reserved: These bits cannot be modified and are always read as 1.
Bit 0—Reserved: This bit can be read or written, but must not be set to 1.
14.3
ADDRA to ADDRD are 16-bit registers, but they are connected to the CPU by an 8-bit data bus.
Therefore, although the upper byte can be be accessed directly by the CPU, the lower byte is read
through an 8-bit temporary register (TEMP).
An A/D data register is read as follows. When the upper byte is read, the upper-byte value is
transferred directly to the CPU and the lower-byte value is transferred into TEMP. Next, when the
lower byte is read, the TEMP contents are transferred to the CPU.
When reading an A/D data register, always read the upper byte before the lower byte. It is possible
to read only the upper byte, but if only the lower byte is read, incorrect data may be obtained.
Figure 14.2 shows the data flow for access to an A/D data register.
Bit 7
TRGE
0
1
CPU Interface
Description
Starting of A/D conversion by an external trigger or 8-bit timer
compare match is disabled
A/D conversion is started at the falling edge of the external trigger
signal (ADTRG) or by an 8-bit timer compare match
Rev.4.00 Aug. 20, 2007 Page 419 of 638
14. A/D Converter
REJ09B0395-0400