ROP
The receive odd parity bit (ROP) controls the expected parity on the receive bus. When ROP
is set to a logic one, the expected parity on the RDP input is odd. When ROP is set to a logic
zero, the parity is even. In SBI bus mode, the parity calculation encompasses the
RDATA[7:0], RPL and RV5 signals. In TelecomBus mode, the parity calculation
encompasses the RDATA[7:0] and optionally RPL and RC1FP as determined by the
INCLRPL and INCLRC1 bits.