INCLOC1FP[4:1]
INCLOPL[4:1]
OOP
The INCLOC1FP bits control whether the OC1FP output signal participates in the outgoing
parity calculations. When INCLOC1FP[x] is set to a logic one, the parity signal includes the
OC1FP output. When INCLOC1FP[x] is set to a logic zero, parity is calculated without
regard to the state of OC1FP. These bits only take effect when in TelecomBus mode.
INCLOC1FP[4:2] are only valid when in 19 MHz mode.
The INCLOPL bits control whether the OPL[x] output signal participates in the outgoing
parity calculations. When INCLOPL[x] is set to a logic one, the parity signal includes the
OPL[x] output. When INCLOPL[x] is set to a logic zero, parity is calculated without regard
to the state of OPL[x]. These bits only take effect when in TelecomBus mode.
INCLOPL[4:2] are only valid when in 19 MHz mode.
The outgoing odd parity bit (OOP) controls the parity generated on the outgoing bus. When
OOP[x] is set to a logic one, the parity on the ODP[x] output is odd. When OOP[x] is set to a
logic zero, the parity is even. In SBI bus mode, the parity calculation encompasses the
ODATA[x][7:0], OPL[x] and OV5[x] signals. In TelecomBus mode, the parity calculation
encompasses the ODATA[x][7:0] and optionally OPL and OC1FP as determined by the
INCLOPL[x] and INCLOC1FP[x] bits. OOP[4:2] are only valid when in 19 MHz mode.