Register 084h: PPP Monitor Byte Error Interrupt Status
This register reports and acknowledges PRBS byte error interrupts for all the time-slots in the
Receive Protection Serial Link.
MONx_ERRI
Bit
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
The Monitor Byte Error Interrupt Status register is the status of the interrupt generated by
each of the 12 STS-1 paths when an error has been detected. The MONx_ERRE is set high
when the monitor is in the synchronized state and when an error in a PRBS byte is detected in
the STS-1 path x. This bit is independent of MONx_ERRE and is cleared after being read.
Type
R
R
R
R
R
R
R
R
R
R
R
R
MON9_ERRI
MON8_ERRI
MON7_ERRI
MON6_ERRI
MON5_ERRI
MON4_ERRI
MON3_ERRI
MON2_ERRI
MON1_ERRI
Function
Unused
Unused
Unused
Unused
MON12_ERRI
MON11_ERRI
MON10_ERRI
Default
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
SBS Telecom Standard Product Data Sheet
Preliminary
203