PNX1501E NXP Semiconductors, PNX1501E Datasheet - Page 765

no-image

PNX1501E

Manufacturer Part Number
PNX1501E
Description
Digital Signal Processors & Controllers (DSP, DSC) MEDIA PROCESSOR PNX15XX/266MHZ
Manufacturer
NXP Semiconductors
Datasheet

Specifications of PNX1501E

Product
DSPs
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
SOT-795
Minimum Operating Temperature
0 C
Lead Free Status / Rohs Status
 Details
Other names
PNX1501E,557

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PNX1501E
Manufacturer:
PHILIPS
Quantity:
5
Part Number:
PNX1501E,557
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
PNX1501E/G
Manufacturer:
NXP Semiconductors
Quantity:
135
Part Number:
PNX1501E/G
Manufacturer:
MICROCHIP
Quantity:
12 000
Part Number:
PNX1501E/G
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Philips Semiconductors
Volume 1 of 1
Table 5: Status Codes
12NC 9397 750 14321
Product data sheet
Status
Code
STA
0xA0
0xA8
0xB0
0xB8
0xC0
Bus/Module
Status
A STOP condition
or repeated
START condition
has been received
while still
addressed as SLV/
(REC or TRX) (But
for SLV/TRX a
violation of I
format)
Own SLA+R has
been received;
ACK has been
returned
Arbitration lost in
SLA+R/W as
master; Own
SLA+R has been
received; ACK has
been received
Data byte in DAT
has been
transmitted; ACK
has been received
Data byte in DAT
has been
transmitted; NOT
ACK has been
received (AA = X)
2
…Continued
C bus
Application Software Response
To/From DAT
No STA action 0
No STA action 0
No STA action 1
No STA action 1
Load data byte X
Load data byte X
Load data byte X
Load data byte X
Load data byte X
Load data byte X
No STA action 0
No STA action 0
No STA action 1
No STA action 1
To CON
STA
Rev. 2 — 1 December 2004
STO
0
0
0
0
0
0
0
0
0
0
0
0
0
0
SI
0
0
0
0
0
0
0
0
0
0
0
0
0
0
AA
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Next Action Taken
Switched to “not addressed” SLV mode; no
recognition of own SLA or general call
address.
Switched to “not addressed” SLV mode;
Own SLA will be recognized; general call
address will be recognized if ADR(0) =’1’.
Switched to “not addressed” SLV mode; no
recognition of own SLA or general call
address. A START condition will be
transmitted when the bus becomes free.
Switched to “not addressed” SLV mode;
own SLA will be recognized; general call
address will be recognized if ADR(0) =’1’. A
START condition will be transmitted when
the bus becomes free.
Last data byte will be transmitted and ACK
bit will be received.
Data byte will be transmitted; ACK bit will be
received.
Last data byte will be transmitted and ACK
bit will be received.
Data byte will be transmitted; ACK bit will be
received.
Last data byte will be transmitted and ACK
bit will be received.
Data byte will be transmitted; ACK bit will be
received.
Switched to “not addressed” SLV mode; no
recognition of own SLA or general call
address.
Switched to “not addressed” SLV mode;
own SLA will be recognized; general call
address will be recognized if ADR(0) =’1’.
Switched to “not addressed” SLV mode; no
recognition of own SLA or general call
address. A START condition will be
transmitted when the bus becomes free.
Switched to “not addressed” SLV mode;
own SLA will be recognized; general call
address will be recognized if ADR(0) =’1’. A
START condition will be transmitted when
the bus becomes free.
© Koninklijke Philips Electronics N.V. 2002-2003-2004. All rights reserved.
PNX15xx Series
Chapter 25: I
2
C Interface
25-15

Related parts for PNX1501E