EP4CE55F23C8N Altera, EP4CE55F23C8N Datasheet - Page 248

no-image

EP4CE55F23C8N

Manufacturer Part Number
EP4CE55F23C8N
Description
IC CYCLONE IV FPGA 55K 484FBGA
Manufacturer
Altera
Series
CYCLONE® IV Er

Specifications of EP4CE55F23C8N

Number Of Logic Elements/cells
55856
Number Of Labs/clbs
3491
Total Ram Bits
2340000
Number Of I /o
324
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
484-FBGA
Family Name
Cyclone IV
Number Of Logic Blocks/elements
55856
# I/os (max)
324
Logic Cells
55856
Ram Bits
2396160
Operating Temp Range
0C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
484
Package Type
FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4CE55F23C8N
Manufacturer:
ALTERA
Quantity:
852
Part Number:
EP4CE55F23C8N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4CE55F23C8N
Manufacturer:
ALTERA
0
Part Number:
EP4CE55F23C8N
Manufacturer:
ALTERA
Quantity:
20 000
Part Number:
EP4CE55F23C8N
0
9–2
User Mode Error Detection
Cyclone IV Device Handbook, Volume 1
1
1
During configuration, Cyclone IV devices use the same methodology to calculate the
CRC value based on the frame of data that is received and compares it against the
frame CRC value in the data stream. Configuration continues until either the device
detects an error or all the values are calculated.
In addition to the frame-based CRC value, the Quartus II software generates a 32-bit
CRC value for the whole configuration bit stream. This 32-bit CRC value is stored in
the 32-bit storage register at the end of the configuration and is used for user mode
error detection that is discussed in
User mode error detection is available in Cyclone IV GX and Cyclone IV E devices
with 1.2-V core voltage. Cyclone IV E devices with 1.0-V core voltage do not support
user mode error detection.
Soft errors are changes in a configuration random-access memory (CRAM) bit state
due to an ionizing particle. Cyclone IV devices have built-in error detection circuitry
to detect data corruption by soft errors in the CRAM cells.
This error detection capability continuously computes the CRC of the configured
CRAM bits based on the contents of the device and compares it with the
pre-calculated CRC value obtained at the end of the configuration. If the CRCs match,
there is no error in the current configuration CRAM bits. The process of error
detection continues until the device is reset (by setting nCONFIG to low).
The Cyclone IV device error detection feature does not check memory blocks and I/O
buffers. These device memory blocks support parity bits that are used to check the
contents of memory blocks for any error. The I/O buffers are not verified during error
detection because the configuration data uses flip-flops as storage elements that are
more resistant to soft errors. Similar flip-flops are used to store the pre-calculated CRC
and other error detection circuitry option bits.
The error detection circuitry in Cyclone IV devices uses a 32-bit CRC IEEE 802
standard and a 32-bit polynomial as the CRC generator. Therefore, a single 32-bit CRC
calculation is performed by the device. If a soft error does not occur, the resulting
32-bit signature value is 0x00000000, that results in a 0 on the CRC_ERROR output
signal. If a soft error occurs in the device, the resulting signature value is non-zero and
the CRC_ERROR output signal is 1.
You can inject a soft error by changing the 32-bit CRC storage register in the CRC
circuitry. After verifying the induced failure, you can restore the 32-bit CRC value to
the correct CRC value with the same instruction and inserting the correct value.
Before updating it with a known bad value, Altera recommends reading out the
correct value.
“User Mode Error
Chapter 9: SEU Mitigation in Cyclone IV Devices
Detection”.
© February 2010 Altera Corporation
User Mode Error Detection

Related parts for EP4CE55F23C8N