AT32UC3A1256AU Atmel Corporation, AT32UC3A1256AU Datasheet - Page 313

no-image

AT32UC3A1256AU

Manufacturer Part Number
AT32UC3A1256AU
Description
Manufacturer
Atmel Corporation

Specifications of AT32UC3A1256AU

Flash (kbytes)
256 Kbytes
Pin Count
100
Max. Operating Frequency
66 MHz
Cpu
32-bit AVR
# Of Touch Channels
32
Hardware Qtouch Acquisition
No
Max I/o Pins
69
Ext Interrupts
69
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device + OTG
Spi
6
Twi (i2c)
1
Uart
4
Ssc
1
Ethernet
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Dac Channels
2
Dac Resolution (bits)
16
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
64
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.0-3.6 or (1.65-1.95+3.0-3.6)
Operating Voltage (vcc)
3.0-3.6 or (1.65-1.95+3.0-3.6)
Fpu
No
Mpu / Mmu
Yes / No
Timers
10
Output Compare Channels
16
Input Capture Channels
6
Pwm Channels
13
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3A1256AU-AUR
Manufacturer:
Atmel
Quantity:
10 000
32058K AVR32-01/12
Figure 26-10. Start Frame Delimiter
26.7.3.3
Figure 26-11. Bit Resynchronization
26.7.3.4
Drift Compensation
Asynchronous Receiver
Oversampling
16x Clock
Sampling
point
RXD
Drift compensation is available only in 16X oversampling mode. An hardware recovery system
allows a larger clock drift. To enable the hardware system, the bit in the MAN register must be
set. If the RXD edge is one 16X clock cycle from the expected edge, this is considered as nor-
mal jitter and no corrective actions is taken. If the RXD event is between 4 and 2 clock cycles
before the expected edge, then the current period is shortened by one clock cycle. If the RXD
event is between 2 and 3 clock cycles after the expected edge, then the current period is length-
ened by one clock cycle. These intervals are considered to be drift and so corrective actions are
automatically taken.
If the USART is programmed in asynchronous operating mode (SYNC = 0), the receiver over-
samples the RXD input line. The oversampling is either 16 or 8 times the Baud Rate clock,
depending on the OVER bit in the Mode Register (MR).
Manchester
Manchester
Manchester
encoded
encoded
encoded
data
data
data
Preamble Length
Synchro.
Txd
Txd
Txd
Error
is set to 0
Synchro.
SFD
SFD
SFD
Jump
DATA
One bit start frame delimiter
Expected edge
Tolerance
start frame delimiter
start frame delimiter
DATA
DATA
Command Sync
Jump
Sync
Data Sync
Synchro.
Error
AT32UC3A
313

Related parts for AT32UC3A1256AU