peb3456 Infineon Technologies Corporation, peb3456 Datasheet - Page 269

no-image

peb3456

Manufacturer Part Number
peb3456
Description
Channelized T3 Termination With Ds3 Framer, M13 Multiplexer, T1/ E1 Framers And 256 Channel Hdlc/ppp Controller
Manufacturer
Infineon Technologies Corporation
Datasheet
SAIS
SAISA
Data Sheet
This bit enables transmission of the DS3 idle code (’1010’ between
overhead bits, X-bits all ‘1’s, C-bits all ‘0’s).
0
1
Send AIS in DS3 output and on DS3 loop
This bit enables transmission of AIS on the DS3 output. If the DS3 is
additionally switched to local DS3 loopback mode the DS3 signal
including AIS is mirrored to the receiver. The AIS code transmitted
depends on D3TCFG.AISC.
0
1
Send AIS at DS3 output
This bit enables transmission of AIS on the DS3 output. If the DS3 signal
is switched into local DS3 loopback mode the DS3 signal without AIS
code is mirrored to the DS3 receiver. The AIS code transmitted depends
on D3TCFG.AISC.
0
1
Normal operation.
Send DS3 idle code.
Normal operation.
Enable transmission of AIS.
Normal operation.
Enable transmission of AIS.
269
Register Description
PEB 3456 E
05.2001