peb3456 Infineon Technologies Corporation, peb3456 Datasheet - Page 374

no-image

peb3456

Manufacturer Part Number
peb3456
Description
Channelized T3 Termination With Ds3 Framer, M13 Multiplexer, T1/ E1 Framers And 256 Channel Hdlc/ppp Controller
Manufacturer
Infineon Technologies Corporation
Datasheet
Table 8-26
Data Sheet
XRES XREP
1
0
0
0
0
0
0
0
0
0
0
1
1
0
0
1
1
-
Signalling Controller Transmit Commands
OBI
0/1
0/1
0/1
0/1
0/1
0/1
0
0
-
XHF
1
1
1
1
0
0
0
0
-
XTF
0
0
0
0
1
1
1
1
-
XME Function
374
0
1
0
1
0
1
0
1
-
Reset Port
Transmit HDLC Frames
Send FIFO content as HDLC frame.
End Transmit HDLC
Send FIFO content as HDLC frame.
Add CRC (if enabled) and flag after last
byte stored in FIFO.
Repeat HDLC Frame
Send FIFO content as HDLC frame.
Add CRC (if enabled) and flag after last
byte stored in FIFO. Then repeat
transmission of FIFO content.
Stop Repeat HDLC Frame
Stop transmission after last byte stored
in FIFO. This command is issued when
repetitive transmission started by
command ’Repeat HDLC Frame’ shall
be stopped.
Transmit Transparent
Send FIFO content in transparent
mode.
End Transmit Transparent
Send FIFO content in transparent
mode. End transmission after last byte
stored in FIFO.
Repeat Transmit Transparent
Send FIFO content in transparent
mode. Repeat transmission of FIFO
content after last byte was sent.
Stop Repeat Transmit Transparent
Stop transparent transmission after
last byte stored in FIFO. This
command is issued when repetitive
transmission started by command
’Repeat transmit transparent’ shall be
stopped.
Register Description
PEB 3456 E
05.2001