PCD
T1/E1 Receive Pulse Count Detection Register
Access
Address
Reset Value
PCD
Data Sheet
15
0
0
0
: read/write
: 0B
: 0015
Pulse Count Detection
A ’Loss of Signal’ alarm will be detected, if the incoming data stream has
zero octets for a programmable number T of consecutive octets. The
number T is programmable via the PCD register and can be calculated
as follows:
T = 8*(PCD+1), 1
E.g. PCD = 21 sets loss of signal threshold to 176 (=(21+1)*8) zeros.
Note: For T1 mode time detection interval has cumulative uncertainty
0
H
H
of 1 per 193 clocks.