MC68HC908QY2 MOTOROLA [Motorola, Inc], MC68HC908QY2 Datasheet - Page 136

no-image

MC68HC908QY2

Manufacturer Part Number
MC68HC908QY2
Description
Microcontrollers
Manufacturer
MOTOROLA [Motorola, Inc]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
MC68HC908QY2CDT
Quantity:
2 667
Company:
Part Number:
MC68HC908QY2CDT
Quantity:
2 667
Part Number:
MC68HC908QY2CPE
Manufacturer:
FREESCALE
Quantity:
7 762
Part Number:
MC68HC908QY2MDTE
Manufacturer:
Freescale Semiconductor
Quantity:
135
Part Number:
MC68HC908QY2MDTE
Manufacturer:
Freescale
Quantity:
204
Part Number:
MC68HC908QY2MDTE
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MC68HC908QY2MP
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MC68HC908QY2MPE
Manufacturer:
Freescale
Quantity:
2 304
Part Number:
MC68HC908QY2VPE
Manufacturer:
Freescale Semiconductor
Quantity:
135
Timer Interface Module (TIM)
10.5.4.1 Unbuffered PWM Signal Generation
136
MC68HC908QY4•MC68HC908QT4•MC68HC908QY2•MC68HC908QT2•MC68HC908QY1•MC68HC908QT1
The value in the TIM counter modulo registers and the selected
prescaler output determines the frequency of the PWM output. The
frequency of an 8-bit PWM signal is variable in 256 increments. Writing
$00FF (255) to the TIM counter modulo registers produces a PWM
period of 256 times the internal bus clock period if the prescaler select
value is 000. See
The value in the TIM channel registers determines the pulse width of the
PWM output. The pulse width of an 8-bit PWM signal is variable in 256
increments. Writing $0080 (128) to the TIM channel registers produces
a duty cycle of 128/256 or 50%.
Any output compare channel can generate unbuffered PWM pulses as
described in
unbuffered because changing the pulse width requires writing the new
pulse width value over the old value currently in the TIM channel
registers.
An unsynchronized write to the TIM channel registers to change a pulse
width value could cause incorrect operation for up to two PWM periods.
For example, writing a new value before the counter reaches the old
value but after the counter reaches the new value prevents any compare
during that PWM period. Also, using a TIM overflow interrupt routine to
write a new, smaller pulse width value may cause the compare to be
missed. The TIM may pass the new value before it is written.
TCHx
OVERFLOW
Timer Interface Module (TIM)
10.5.4 Pulse Width Modulation
Figure 10-3. PWM Period and Pulse Width
PULSE
WIDTH
10.10.1 TIM Status and Control
PERIOD
COMPARE
OUTPUT
OVERFLOW
COMPARE
OUTPUT
(PWM). The pulses are
OVERFLOW
Register.
MOTOROLA
COMPARE
OUTPUT

Related parts for MC68HC908QY2