EP3C10M164C8N Altera, EP3C10M164C8N Datasheet - Page 319

IC CYCLONE III FPGA 402MHZ BGA-164

EP3C10M164C8N

Manufacturer Part Number
EP3C10M164C8N
Description
IC CYCLONE III FPGA 402MHZ BGA-164
Manufacturer
Altera
Series
Cyclone IIIr
Datasheets

Specifications of EP3C10M164C8N

No. Of Logic Blocks
645
Family Type
Cyclone III
No. Of I/o's
106
I/o Supply Voltage
3.3V
Operating Frequency Max
402MHz
Operating Temperature Range
0°C To +85°C
Family Name
Cyclone III
Number Of Logic Blocks/elements
10320
# I/os (max)
106
Frequency (max)
402MHz
Process Technology
65nm
Operating Supply Voltage (typ)
1.2V
Logic Cells
10320
Ram Bits
423936
Operating Supply Voltage (min)
1.15V
Operating Supply Voltage (max)
1.25V
Operating Temp Range
0C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
164
Package Type
MBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP3C10M164C8N
Manufacturer:
ALTERA
0
Electrical Characteristics
Operating Conditions
© December 2009
CIII52002-1.2
1
1
Altera Corporation
This chapter describes the electric characteristics, switching characteristics, and I/O
timing for Cyclone
The following sections provide information about the absolute maximum ratings,
recommended operating conditions, DC characteristics, and other specifications for
Cyclone III LS devices.
When Cyclone III LS devices are implemented in a system, they are rated according to
a set of defined parameters. To maintain the highest possible performance and
reliability of Cyclone III LS devices, you must consider the operating requirements in
this chapter. Cyclone III LS devices are offered in commercial and industrial grades.
Commercial devices are offered in –7 (fastest) and –8 speed grades. Industrial devices
are offered only in –7 speed grade.
In this chapter, a prefix associated with the operating temperature range is attached to
the speed grades—commercial with a “C” prefix; industrial with an “I” prefix. For
example, commercial devices are described as C7 and C8 per respective speed grades.
Industrial devices are described as I7.
Absolute Maximum Ratings
Absolute maximum ratings define the maximum operating conditions for
Cyclone III LS devices. The values are based on experiments conducted with the
device and theoretical modeling of breakdown and damage mechanisms. The
functional operation of the device is not implied at these conditions.
absolute maximum ratings for Cyclone III LS devices.
Conditions beyond those listed in
device. Additionally, device operation at the absolute maximum ratings for extended
periods of time may have adverse effects on the device. All parameters representing
voltages are measured with respect to ground.
Table 2–1. Cyclone III LS Devices Absolute Maximum Ratings
V
V
V
V
V
V
Symbol
C CINT
C CIO
C CA
C CD_P LL
C CB AT
I
Supply voltage for internal logic
Supply voltage for output buffers
Supply (analog) voltage for PLL regulator
Supply (digital) voltage for PLL
Battery back-up power supply for design
security volatile key register
DC input voltage
®
III LS devices. A glossary is also included for your reference.
Parameter
2. Cyclone III LS Device Data Sheet
Table 2–1
may cause permanent damage to the
(Note 1)
Min
–0.5
–0.5
–0.5
–0.5
–0.5
–0.5
Cyclone III Device Handbook, Volume 2
(Part 1 of 2)
Max
3.75
3.75
3.95
Table 2–1
1.8
3.9
1.8
lists the
Unit
V
V
V
V
V
V

Related parts for EP3C10M164C8N