PEB3081FV14XP Lantiq, PEB3081FV14XP Datasheet - Page 156

PEB3081FV14XP

Manufacturer Part Number
PEB3081FV14XP
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEB3081FV14XP

Number Of Line Interfaces
1
Control Interface
HDLC
Lead Free Status / Rohs Status
Compliant
PEB 3081
PEF 3081
Detailed Register Description
Preliminary
4.3.8
MON_CR - Control Register Monitor Data
Value after reset: 40
H
7
0
MON_CR DPS
EN_
0
0
0
CS2-0
RD/WR (54)
MON
For general information please refer to
Chapter
3.7.3.
DPS ... Data Port Selection
0: The Monitor data is output on DD and input from DU
1: The Monitor data is output on DU and input from DD
EN_MON ... Enable Output
0: The Monitor data input and output is disabled
1: The Monitor data input and output is enabled
CS2-0 ... MONITOR Channel Selection
000: The MONITOR data is input/output on MON0 (3rd timeslot on IOM-2)
001: The MONITOR data is input/output on MON1 (7th timeslot on IOM-2)
010: The MONITOR data is input/output on MON2 (11th timeslot on IOM-2)
:
111: The MONITOR data is input/output on MON7 (31st timeslot on IOM-2)
Note: The reset value is determined by the channel select pins CH2-0 which are directly
mapped to CS2-0.
Data Sheet
156
2000-09-27

Related parts for PEB3081FV14XP