PEB3081FV14XP Lantiq, PEB3081FV14XP Datasheet - Page 72

PEB3081FV14XP

Manufacturer Part Number
PEB3081FV14XP
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEB3081FV14XP

Number Of Line Interfaces
1
Control Interface
HDLC
Lead Free Status / Rohs Status
Compliant
Preliminary
Indication
Data Sheet
Timing
Reset
Receiver not
Synchronous
Activation Request
Illegal Code
Violation
Activation Indication AI
Deactivation
Indication
Abbr.
TIM
RES
RSY
AR
CVR
DI
Code
0000
0001
0100
1000
1011
1100
1111
procedure in G1.
INFO 0. No reaction to incoming infos.
RES is an unconditional command.
Receiver is not synchronous
INFO 0 received from terminal. Activation
proceeds.
Illegal code violation received. This
function has to be enabled in
TR_CONF0.EN_ICV.
completed.
Timer (32 ms) expired or INFO 0 received
for a duration of 16 ms after deactivation
request
Remark
Interim indication during activation
Reset of state machine. Transmission of
Synchronous receiver, i.e. activation
72
Description of Functional Blocks
PEB 3081
PEF 3081
2000-09-27