– transmission of special test signals on the S/T interface according to the modified AMI
Two kinds of test signals may be transmitted by the SBCX-X:
– The single pulses are of alternating polarity. One pulse is transmitted in each frame
– The continuous pulses are of alternating polarity. 48 pulses are transmitted in each
Data Sheet
code are initiated via a C/I command written in CIX0 register (see
resulting in a frequency of the fundamental mode of 2 kHz. The corresponding C/I
command is SSP (Send Single Pulses).
frame resulting in a frequency of the fundamental mode of 96 kHz. The corresponding
C/I command is SCP (Send Continuous Pulses).
54
Description of Functional Blocks
Chapter
PEB 3081
PEF 3081
2000-09-27
3.5.4)
Related parts for PEB3081FV14XP
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
![PEB22811H-V13X](/images/manufacturer_photos/0/3/379/lantiq_tmb.jpg)
Part Number:
Description:
Manufacturer:
Lantiq
Datasheet:
![ADM6996L-AA-T-1](/images/manufacturer_photos/0/3/379/lantiq_tmb.jpg)
Part Number:
Description:
Manufacturer:
Lantiq
Datasheet:
![PEF22810T-V21TR](/images/manufacturer_photos/0/3/379/lantiq_tmb.jpg)
Part Number:
Description:
Manufacturer:
Lantiq
Datasheet: