PMON Event Interrupt Indication Register
T_INACT_I
M_INACT_I
TM_ISOP_I
TM_IEOP_I
MT_ISOP_I
MT_IEOP_I
TM_PKTCD_I
MT_PKTCD_I
T_LOCKUN_I
M_LOCKUN_I
T_DCLKLOS_I
IDT IDT88K8483
Field
Table 139 PMON Event Interrupt Indication Register (Block Base=0x0F00, Register Offset=0x00)
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Read /
Write
0:0
0:4
0:5
0:6
0:7
1:0
1:1
1:2
0:1
0:2
0:3
Bits
1
1
1
1
1
1
1
1
1
1
1
Length
0
0
0
0
0
0
0
0
0
0
0
Reset
State
136 of 162
Tributary ingress inactive LP event.
Read 1: Indicates occurrence of the event.
Read 0: Indicates that the event has not occurred.
Write 1: Clear the bit.
Main ingress inactive LP event.
Read 1: Indicates occurrence of the event.
Read 0: Indicates that the event has not occurred.
Write 1: Clear the bit.
T-M illegal SOP event.
Read 1: Indicates occurrence of the event.
Read 0: Indicates that the event has not occurred.
Write 1: Clear the bit.
T-M illegal EOP event.
Read 1: Indicates occurrence of the event.
Read 0: Indicates that the event has not occurred.
Write 1: Clear the bit.
M-T illegal SOP event.
Read 1: Indicates occurrence of the event.
Read 0: Indicates that the event has not occurred.
Write 1: Clear the bit.
M-T illegal EOP event.
Read 1: Indicates occurrence of the event.
Read 0: Indicates that the event has not occurred.
Write 1: Clear the bit.
T-M packet cut down event.
Read 1: Indicates occurrence of the event.
Read 0: Indicates that the event has not occurred.
Write 1: Clear the bit.
M-T packet cut down event.
Read 1: Indicates occurrence of the event.
Read 0: Indicates that the event has not occurred.
Write 1: Clear the bit.
Tributary SPI4 ingress locker unavailable event.
Read 1: Indicates occurrence of the event.
Read 0: Indicates that the event has not occurred.
Write 1: Clear the bit.
Main SPI4 ingress locker unavailable event.
Read 1: Indicates occurrence of the event.
Read 0: Indicates that the event has not occurred.
Write 1: Clear the bit.
Tributary ingress data clock loss event.
Read 1: Indicates occurrence of the event.
Read 0: Indicates that the event has not occurred.
Write 1: Clear the bit.
Description