SAF-C164SM Infineon Technologies, SAF-C164SM Datasheet - Page 292

no-image

SAF-C164SM

Manufacturer Part Number
SAF-C164SM
Description
16-Bit CMOS Microcontroller
Manufacturer
Infineon Technologies
Datasheet
In Center Aligned Mode the compare timer T12 counts up starting at 0000
reaching the period value stored in register T12P the count direction is reversed and the
timer counts down. The output signals are switched to their active/passive state upon a
match with the compare value while counting up/down. Center aligned mode is
supported by compare timer T12 only.
The compare timers T12 and T13 are free running timers which are clocked with a
programmable frequency of
The respective output signals are changed (if appropriate) when the timer reaches the
programmed compare value. For switching the output signals COUT60 … COUT62 the
contents of the timer plus the offset value are compared against the compare value.
Timer T12 can operate in either edge aligned or center aligned PWM mode (see
Figure
Timer T13 can operate in edge aligned mode without edge delay.
Figure 17-3 CAPCOM6 Basic Operating Modes
User’s Manual
Compare Timer T12 in Edge Aligned Mode
a) Standard PWM
Compare Timer T12 in Center Aligned Mode
c) Symmetrical PWM
Period
Value
Compare
Value
0000
CC6x
COUT6x
Period
Value
Compare
Value
0000
CC6x
COUT6x
: Interrupt can be generated
H
H
17-3), with or without a constant edge delay (a or b in
f
CPU
to
f
CPU
Period
Value
Compare
Value
Offset
CC6x
COUT6x
Period
Value
Compare
Value
Offset
CC6x
COUT6x
b) Standard PWM with dead time (
d) Symmetrical PWM with dead time (
/128.
17-3
{
{
Capture/Compare Unit CAPCOM6
t
t
OFF
OFF
Figure
MCB04110
MCB03356
t
OFF
C164CM/C164SM
t
OFF
17-3).
t
)
OFF
Derivatives
)
V1.0, 2002-02
Initial value ‘0’
Initial value ‘1’
H
. Upon