SAF-C164SM Infineon Technologies, SAF-C164SM Datasheet - Page 307

no-image

SAF-C164SM

Manufacturer Part Number
SAF-C164SM
Description
16-Bit CMOS Microcontroller
Manufacturer
Infineon Technologies
Datasheet
17.7
The trap function switches selectable output lines of the CAPCOM6 to predefined levels
simultaneously. The trap function is triggered by an external signal connected to input
CTRAP. This feature provides a very efficient means of protecting external circuitry,
such as power bridges for inverters or motors, which are connected to the CAPCOM6’s
output lines. Register TRCON enables and controls the trap function, register
CC6MCON or P1L provides the output levels during trap state.
Figure 17-11
aligned mode.
Figure 17-11 Trap Function
User’s Manual
Notes
Reference Point 1):
Input CTRAP is activated,
the outputs
immediately switch to their
trap level.
Reference Point 2):
Input CTRAP is inactive,
the outputs switch to their
programmed level
synchronized to a
new timer period.
Secure Trap State
During trap state the
outputs CC6x and COUT6x
which are selected for T13
modulation are not
modulated with T13’s
output signal but rather
with its initial value.
Trap Function
shows examples for a trap state in edge aligned mode and in center
Trap Function In Edge Aligned Mode
Trap Function In Center Aligned Mode
Period
Value
Compare
Value
Offset
CCx
COUTx
CTRAP
Period
Value
Compare
Value
Offset
CCx
COUTx
CTRAP
{
{
17-18
1)
1)
Trap State
Trap State
Capture/Compare Unit CAPCOM6
T12 + T12OF
T12 + T12OF
Trap State
Trap State
T12
2)
T12
C164CM/C164SM
Derivatives
V1.0, 2002-02
MCB04114
2)
MCT02606

Related parts for SAF-C164SM