EP3SL150F780I3N Altera, EP3SL150F780I3N Datasheet - Page 436

no-image

EP3SL150F780I3N

Manufacturer Part Number
EP3SL150F780I3N
Description
Stratix III
Manufacturer
Altera
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP3SL150F780I3N
Manufacturer:
PMI
Quantity:
4
Part Number:
EP3SL150F780I3N
Manufacturer:
AVX
Quantity:
2
Part Number:
EP3SL150F780I3N
Manufacturer:
ALTERA
Quantity:
546
Part Number:
EP3SL150F780I3N
Manufacturer:
XILINX
0
Part Number:
EP3SL150F780I3N
Manufacturer:
ALTERA
0
Part Number:
EP3SL150F780I3N
Manufacturer:
ALTERA
Quantity:
220
Part Number:
EP3SL150F780I3N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Company:
Part Number:
EP3SL150F780I3N
Quantity:
280
Part Number:
EP3SL150F780I3N WWW.YIBEIIC.COM
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Dedicated Remote System Upgrade Circuitry
12–14
Stratix III Device Handbook, Volume 1
User Watchdog Timer
The user watchdog timer prevents a faulty application configuration
from stalling the device indefinitely. The system uses the timer to detect
functional errors after an application configuration is successfully loaded
into the Stratix III device.
The user watchdog timer is a counter that counts down from the initial
value loaded into the remote system upgrade control register by the
factory configuration. The counter is 29-bits wide and has a maximum
count value of 2
specify only the most significant 12 bits. The granularity of the timer
setting is 2
10-MHz internal oscillator.
10-MHz internal oscillator.
The user watchdog timer begins counting once the application
configuration enters device user mode. This timer must be periodically
reloaded or reset by the application configuration before the timer expires
by asserting RU_nRSTIMER. If the application configuration does not
reload the user watchdog timer before the count expires, a time-out signal
is generated by the remote system upgrade dedicated circuitry. The
time-out signal tells the remote system upgrade circuitry to set the user
watchdog timer status bit (Wd) in the remote system upgrade status
register and reconfigures the device by loading the factory configuration.
The user watchdog timer is not enabled during the configuration cycle of
the device. Errors during configuration are detected by the CRC engine.
Also, the timer is disabled for factory configurations. Functional errors
should not exist in the factory configuration since it is stored and
validated during production and is never updated remotely.
1
Note to
(1)
Table 12–6. 10-MHz Internal Oscillator Specifications
Minimum
These values are preliminary.
Table
5
The user watchdog timer is disabled in factory configurations
and during the configuration cycle of the application
configuration. It is enabled after the application configuration
enters user mode.
15
cycles. The cycle time is based on the frequency of the
12–6:
29
. When specifying the user watchdog timer value,
Typical
6.5
Table 12–6
specifies the operating range of the
Maximum
10
Note (1)
Altera Corporation
October 2007
Units
MHz