ALXD800EEXJCVD C3 AMD (ADVANCED MICRO DEVICES), ALXD800EEXJCVD C3 Datasheet - Page 33

no-image

ALXD800EEXJCVD C3

Manufacturer Part Number
ALXD800EEXJCVD C3
Description
Manufacturer
AMD (ADVANCED MICRO DEVICES)
Datasheet

Specifications of ALXD800EEXJCVD C3

Operating Temperature (min)
0C
Operating Temperature (max)
85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Lead Free Status / RoHS Status
Compliant
Signal Definitions
3.4
3.4.1
AMD Geode™ LX Processors Data Book
Signal Name
SYSREF
DOTREF
INTA#
IRQ13
CIS
SUSPA#
PW0, PW1
Signal Descriptions
System Interface Signals
(Strap)
(Strap)
(Strap)
AL18,
AD28
AB29
AE29
AC31
AJ17
Ball
AB1
Y31
No.
Type
(PD)
(PD)
I/O
I/O
I/O
I/O
I/O
I
I
33, 66 MHz
0-300 Mb/s
0-66 Mb/s
0-66 Mb/s
0-66 Mb/s
0-66 Mb/s
48 MHz
f
3.3
3.3
3.3
3.3
3.3
3.3
3.3
V
Description
System Reference. PCI input clock; typically 33 or
66 MHz.
Dot Clock Reference. Input clock for DOTCLK PLL.
Interrupt. Interrupt from the AMD Geode LX proces-
sor to the CS5536 companion device (open drain).
Interrupt Request Level 13. When a floating point
error occurs, the AMD Geode LX processor asserts
IRQ13. The floating point interrupt handler then per-
forms an OUT instruction to I/O address F0h or F1h.
The AMD Geode LX processor accepts either of
these cycles and clears IRQ13.
IRQ13 is an output during normal operation. It is an
input at reset and functions as a boot strap for tester
features on a board. It must be pulled low for normal
operation.
CPU Interface Serial. The GLCP I/O companion
interface uses the CIS signal to create a serial bus. It
contains INTR#, SUSP#, NMI#, INPUT_DIS#,
OUTPUT_DIS#, and SMI#. For details see
"GIO_PCI Serial Protocol" on page 538.
Suspend Acknowledge. Suspend Acknowledge
indicates that the AMD Geode LX processor has
entered low-power Suspend mode as a result of
SUSP# assertion (as part of the packet asserted on
the CIS signal) or execution of a HLT instruction.
(The AMD Geode LX processor enters Suspend
mode following execution of a HLT instruction if the
SUSPONHLT bit, MSR 00001210h[0], is set.)
The SYSREF input may be stopped after SUSPA#
has been asserted to further reduce power con-
sumption if the system is configured for 3 Volt Sus-
pend mode.
SUSPA# is an output during normal operation. It is
an input at reset and functions as a boot strap for fre-
quency selection on a board. It must be pulled high
or low to invoke the strap.
PowerWise Controls. Used for debug.
PWx is an output during normal operation. It is an
input at reset and functions as a boot strap for fre-
quency selection on a board. It must be pulled high
or low to invoke the strap.
33234H
33