ALXD800EEXJCVD C3 AMD (ADVANCED MICRO DEVICES), ALXD800EEXJCVD C3 Datasheet - Page 654

no-image

ALXD800EEXJCVD C3

Manufacturer Part Number
ALXD800EEXJCVD C3
Description
Manufacturer
AMD (ADVANCED MICRO DEVICES)
Datasheet

Specifications of ALXD800EEXJCVD C3

Operating Temperature (min)
0C
Operating Temperature (max)
85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Lead Free Status / RoHS Status
Compliant
Exceptions
None.
Notes
None.
8.3.4.10 SMINT - Enter System Management Mode
Operation
654
IF (CPL<>0 OR (SMM_INST_EN=0 AND SMM=0 AND DMM=0))
ELSE
Opcode
0F 38
#UD;
SMM_HEADER[SMM_CTL] <= SMM_CTL;
SMM_HEADER[I/O_DATA] <= 0;
SMM_HEADER[I/O_ADDRESS] <= 0;
SMM_HEADER[I/O_SIZE] <= 0;
SMM_HEADER[SMM_FLAGS] <= SMM_FLAGS;
SMM_HEADER[SS_FLAGS] <= SS.FLAGS;
SMM_HEADER[CS_LIMIT] <= CS.LIMIT;
SMM_HEADER[CS_BASE] <= CS.BASE;
SMM_HEADER[CS_SELECTOR] <= CS.SELECTOR;
SMM_HEADER[CS_FLAGS] <= CS.FLAGS;
SMM_HEADER[NEXT_IP] <= IP OF INSTRUCTIOn after SMINT;
SMM_HEADER[CURRENT_IP] <= IP of SMINT Instruction;
SMM_HEADER[CR0] <= CR0;
SMM_HEADER[EFLAGS] <= eflags;
SMM_HEADER[DR7] <= DR7;
CR0 <= {1’b0, CR0.CD, CR0.NW, 29’h010};
if (!DMM_CTL.DBG_AS_DMI)
SS.flags <= {SS.FLAGS[15:7], 2’b0, SS.FLAGS[4:0]};
CS.FLAGS <= 16’h009a;
CS.SELECTOR <= SMM_BASE >> 4;
CS.BASE <= SMM_BASE;
IF (SMM_LIMIT < 32’g100000)
else
EFLAGS <= 32’h00000002;
SMM_CTL <= {SMM_CTL[31:3],1’b0, SMM_CTL[1], 1’b0};
SMM <= 1;
Jump to CS at offset of 0;
Instruction
SMINT
DR7 <= 32’h00000400;
CS.LIMIT <= SMM_LIMIT;
CS.G <= 1’b0;
CS.LIMIT <= SMM_LIMIT | 32’hfff;
CS.G <= 1’b1;
33234H
Clocks
55
Description
Enter SMM and call the SMI handler
AMD Geode™ LX Processors Data Book
Instruction Set